Installing/mounting
4.3 Proper mounting
Emission cone type and beam angle
Antenna type
Horn
Threaded PVDF
Flanged encapsulated
Hygienic encapsulated
Emission cone
● Keep emission cone free of interference from obstructions such as ladders, pipes, I-beams,
or filling streams.
Access for programming
● Provide easy access for viewing the display and programming via the handheld programmer.
30
Antenna size
1.5"
2"
3"
4"
Process connection
Process connection type
size
2"
Class 150 ASME B16.5
3, 4, 6"
Class 150 ASME B16.5
50A
10K JIS B 2220
80A/100A/150A
10K JIS B 2220
DN50
PN10/16 EN1092-1
DN80/DN100/DN15
PN10/16 EN1092-1
0
2"
Sanitary Clamp according to
ISO 2852
3, 4"
DN50
Aseptic/Hygienic nozzle/slotted
nut according to DIN 11864-1
DN80/DN100
[Form A]
DN50
Aseptic/Hygienic flanged
according to DIN 11864-2
DN80/DN100
[Form A]
DN50
Aseptic/Hygienic Clamp
according to DIN 11864-
DN80/DN100
3 [Form A]
DN50
Hygienic nozzle/slotted nut
according to DIN 11851
DN80/DN100
Type F (50 mm)
Tuchenhagen Varivent
and Type N
(68 mm)
Operating Instructions, 08/2014, A5E32221411-AC
Beam angle
19°
15°
10°
8°
19°
12.8°
9.6°
12.8°
9.6°
12.8°
9.6°
12.8°
9.6°
12.8°
9.6°
12.8°
9.6°
12.8°
9.6°
12.8°
9.6°
12.8°
SITRANS LR250 (FOUNDATION FIELDBUS)