  • Page 1 AXIS T8504–E Outdoor PoE Switch User Manual...
  • Page 2: Table Of Contents

    AXIS T8504–E Outdoor PoE Switch Table of Contents About this manual ......... .
  • Page 3: About This Manual

    Objectives AXIS T8504–E is an outdoor PoE switch. The major benefits of this product is its outdoor capabilities and the capability to extend the maximum reach of the network by an additional 100 meters, to a total of 200 meters, between the switch and the powered devices, while providing up to 2x60 W and 2x30 W to its network-powered PoE devices.
  • Page 4 AXIS T8504–E Outdoor PoE Switch About this manual Message digest algorithm SNMP Simple Network Management Protocol Secure Shell Secure Sockets Layer SysLog System Log TACACS+ Terminal Access Controller Access-Control TFTP Trivial File Transfer Protocol Transport Layer Security VLAN Virtual Local Area Network...
  • Page 5: General Information

    AXIS T8504–E Outdoor PoE Switch General information General information Features A number of features are provided through system network management. • Easy software update during runtime without affecting active PoE ports • Configuration and real-time monitoring using graphical representation of the remote device •...
  • Page 6 AXIS T8504–E Outdoor PoE Switch General information HTTP is a web-based friendly configuration interface. HTTPS-TLS is a secured web-based friendly configuration interface. • SNMP via an SNMP manager application – to monitor the unit over the network (MIB-II RFC1213) and to monitor or...
  • Page 7: First-Time Configuration

    AXIS T8504–E Outdoor PoE Switch General information Authentication password (MD5) = password Privacy password (DES) = password Authentication and encryption mode = MD5+DES SNMPv3 notification Username = trap Authentication password = password Privacy password = password Authentication and encryption mode = None For information about how to recover username and password, see Recover username and password on page 7 .
  • Page 8: Unit Identification Over Ip Network

    Unit boot version, used for software update RST: Power-On Reset reason BOOT: 0=[APP OK] Host: axis followed by unit MAC address axis-00055A034B49 MAC: 00:05:5a:03:4b:49 Unit MAC address VLAN: VLAN status enabled or disabled VLAN_UPLINK_PORT: Ethernet port number used for unit...
  • Page 9: Web Interface

    AXIS T8504–E Outdoor PoE Switch Web interface Web interface Web interface menu Status Go to Status to view the unit status. The page is updated automatically every few seconds. Note The Ethernet network link is always enabled, regardless of PoE configuration (enabled or disabled).
  • Page 10 AXIS T8504–E Outdoor PoE Switch Web interface Network configuration - Go to Network configuration to enable or disable DHCP, configure IPv4, IPv6 and network hostname. Hostname is used by both IPv4 and IPv6 to register the unit name in DHCPv4/v6 server. Note that IPv6 uses the FQDN terminology as hostname.
  • Page 11 AXIS T8504–E Outdoor PoE Switch Web interface Primary server IP address Configure the primary IPv4, IPv6 or hostname to be used to access the main RADIUS/TACACS+ server. Secondary server IP address Configure the secondary IPv4, IPv6 or hostname to be used to access the main RADIUS/TACACS+ server.
  • Page 12 AXIS T8504–E Outdoor PoE Switch Web interface Management uplink port This parameter has no effect on actual VLAN traffic. The management uplink port assists the unit to evaluate if the new VLAN configuration might block the unit from being managed over VLAN from this port.
  • Page 13 AXIS T8504–E Outdoor PoE Switch Web interface Parameter Description Enable notification Enable or disable the following PoE trap reports: • PoE power was provided/removed from powered device • Unit total power consumption exceeds xy% out of max unit power • Unit total power consumption was restored to less than xy% out of max...
  • Page 14 AXIS T8504–E Outdoor PoE Switch Web interface Maintenance Reset - There are four different reset options: • Do a safe restart without losing PoE power resets the internal network manager and the internal Ethernet switch (network will be down for a few seconds), leaving the PoE power unchanged. Powered devices continue normal operations as if no reset is done.
  • Page 15: Ssh Serial Interface

    AXIS T8504–E Outdoor PoE Switch SSH serial interface SSH serial interface The SSH interface is designed for various maintenance tasks such as PoE firmware update etc. It is designed to provide an easy and convenient interface for IT managers who are familiar with SSH. To simplify SSH usage, the SSH interface is menu-driven.
  • Page 16 AXIS T8504–E Outdoor PoE Switch SSH serial interface 2. View network parameters Go to this menu item to get the following information: • In-use IPv4 network parameters — Shows if DHCPv4 is enabled or disabled. Also shows the in-use IPv4 address, IPv4 mask and IPv4 default gateway.
  • Page 17 AXIS T8504–E Outdoor PoE Switch SSH serial interface 7. Reset unit Reset the entire unit including the internal network manager, PoE controller and internal Ethernet switch. Enable or disable auto ping to default gateway. When enabled, the unit verifies proper 8.
  • Page 18: Snmp Monitoring And Configuration

    AXIS T8504–E Outdoor PoE Switch SNMP monitoring and configuration SNMP monitoring and configuration Multiple units can be monitored and managed by using third-party standard network management tools such as HP Openview, IBM Tivoli, SNMPc etc. Enable SNMP The network manager interface supports SNMPv1, SNMPv2 and SNMPv3. The unit accepts and replies to SNMPv1 packets, but since SNMPv1 is obsolete, SNMP traps and notifications are sent in SNMPv2, SNMPv3 or both.
  • Page 19 AXIS T8504–E Outdoor PoE Switch SNMP monitoring and configuration Private MIB The following SNMP OiDs are supported by the SNMP private MIB: OiD name Description Type (R/W) poePortConsumptionPower PoE port power consumption [Watt] poePortMaxPower PoE port maximum available power [Watt] poePortType PoE port type —...
  • Page 20: Syslog Message

    AXIS T8504–E Outdoor PoE Switch SysLog Message SysLog Message The unit sends various event reports to an external IPv4/IPv6 host running a SysLog daemon application. The IPv4/IPv6 host logs the events for future use. Configure SysLog server IP address by browsing to the unit configuration web page if SysLog events are to be sent.
  • Page 21 AXIS T8504–E Outdoor PoE Switch SysLog Message Unit configuration changed is sent when the unit configuration is changed. PoE controller reset is sent when PoE controller reset occurs. PoE controller has no firmware is sent when PoE controller firmware is erased or is corrupted.
  • Page 22: Troubleshooting

    3. EnableSNMPv2 or SNMPv3. Support Should you require any technical assistance, please contact your Axis reseller. If your questions cannot be answered immediately, your reseller will forward your queries through the appropriate channels to ensure a rapid response. If you are connected to the Internet, you can: •...
  • Page 23: Learn More

    Should you require any technical assistance, please contact appropriate channels according to your AVHS license agreement to ensure a rapid response. Should you require any technical assistance, please contact ADP Helpdesk to ensure a rapid response. Learn more! Visit Axis learning center axis.com/academy for useful trainings, webinars, tutorials and guides.