Axis T8504-E User Manual page 16

Outdoor poe switch
Hide thumbs Also See for T8504-E:
Table of Contents

Advertisement

AXIS T8504–E Outdoor PoE Switch
SSH serial interface
2. View network parameters
3. View unit information
Configuration and maintenance menu
Go to Configuration and maintenance menu to configure or reset the unit or to update software.
Menu item
1. Enable/Disable PoE port
2. Download WEB SSL certificate from
TFTP server (reset only web server)
3. Update unit PoE firmware (reset
unit)
4. Restore unit to semi factory default
(excluding IP configuration)
5. Restore unit to full factory default
6. Reset only network manager
Go to this menu item to get the following information:
• In-use IPv4 network parameters — Shows if DHCPv4 is enabled or disabled.
Also shows the in-use IPv4 address, IPv4 mask and IPv4 default gateway.
• In-use IPv6 network parameters — Shows if DHCPv6 is enabled or disabled.
Also shows the in-use IPv6 address, IPv6 prefix and IPv6 default gateway.
IPv6 can report several IPv6 addresses which were obtained automatically in
addition to a static/DHCPv6 IPv6 address.
• In-use DNS network parameters — Information about in-use IPv4/IPv6
domain name server IPs, which are configured statically or obtained by
DHCPv4/DHCPv6.
• More network parameters — Information about the unit MAC address
Go to this menu item to get a summary of unit production parameters:
• Part number — Information about unit marketing part number (T8504–E)
• S/N — Information about unit six-digit serial number
• Product number — Information about unit production number (for internal
use only)
• App ver — Information about network manager software version
• Boot ver — Information about network manager boot version
• Firmware — PoE firmware version
• System up time — Information about the time passed since the unit was
reset or powered up
• System GMT time — Information about unit GMT time as it was obtained from
an NTP server. Whenever the unit is unable to obtain NTP time from an NTP
server, the message "incorrect" is shown.
• System local time — Information about unit local time (GMT plus time zone
shift). Whenever the unit is unable to obtain NTP time from an NTP server,
the message "incorrect" is shown.
Description
Enable or disable a PoE port. Ethernet link remains enabled even when no power is
provided.
Download self-signed or CA signed certificates from a TFTP server, to allow secure web
browsing to the unit with security confirmation by the web browser (green lock in the
web browser URL area)
Update PoE firmware. Update files are downloaded from a TFTP server. PoE functionality is
not available during the firmware update (approximately 5–10 minutes).
Restore the unit configuration to factory default, but leaves the IPv4/IPv6 network
configuration unchanged. This maintains the option to access the unit over the network
as before.
Restore the entire unit to full factory default.
Reset only the internal network manager, which is responsible for unit network
management interfaces such as the web, SSH, SNMP, etc. Internal Ethernet switch is also
reset; the network will be down for a few seconds. Only PoE power is unchanged. Powered
devices continue normal operation as if no reset was done.