AXIS T8504–E Outdoor PoE Switch
Web interface
Parameter
Enable notification
Notify exceeded power usage
(1–99%)
SNMPv3
Parameter
Enable SNMPv3
User name
Authentication password
Privacy password
Authentication and encryption mode
SNMPv3 notification (Trap)
Parameter
User name
Authentication password
Privacy password
Authentication and encryption mode
Remote IPv4/IPv6 SNMP trap managers (v2c/v3)
Parameter
Trap manager #1
Trap manager #2
Description
Enable or disable the following PoE trap reports:
• PoE power was provided/removed from powered device
• Unit total power consumption exceeds xy% out of max unit power
• Unit total power consumption was restored to less than xy% out of max
unit power
If enabled, user is notified whenever unit total power consumption (xy%) percentage out
of unit max power exceeds or drops below specified value.
Description
Enable or disable SNMPv3 support.
Configure SNMPv3 username string.
Configure SNMPv3 password to be used by MD5/SHA.
Configure SNMPv3 password to be used by DES/AES.
Configure the SNMPv3 authentication and encryption mode.
None — no authentication or encryption, which means no security.
MD5 — MD5 authentication with no encryption. Packet can be changed, by can easily be
analyzed by network sniffers.
SHA — SHA authentication with no encryption.
MD5+DES — MD5 authentication and DES encryption
SHA+DES — SHA authentication and DES encryption
MD5+AES — MD5 authentication and AES encryption
SHA+AES — SHA athentication and AES encryption
Description
Configure SNMPv3 notification username string.
Configure SNMPv3 notification password to be used by MD5/SHA.
Configure SNMPv3 notification password to be used by DES/AES.
Configure the SNMPv3 notification authentication and encryption mode.
None — no authentication or encryption, which means no security.
MD5 — MD5 authentication with no encryption. Packet can be changed, by can easily be
analyzed by network sniffers.
SHA — SHA authentication with no encryption.
MD5+DES — MD5 authentication and DES encryption
SHA+DES — SHA authentication and DES encryption
MD5+AES — MD5 authentication and AES encryption
SHA+AES — SHA athentication and AES encryption
Description
Configure the first IPv4/IPv6/DNS name of remote SNMP manager server receiving unit
trap reports such as Cold-Start, etc.
Configure the second IPv4/IPv6/DNS name of remote SNMP manager server receiving
unit trap reports such as Cold-Start, etc.