Axis T8504-E User Manual page 12

Outdoor poe switch
Hide thumbs Also See for T8504-E:
Table of Contents

Advertisement

AXIS T8504–E Outdoor PoE Switch
Web interface
Management uplink port
Management VLAN ID
VLAN ports configuration
Parameter
VLAN mode
Access mode VLAN ID
TRUNK – Filter unknown VLAN
TRUNK VLANs
SNMP configuration
Go to SNMP configuration to configure parameters applicable to SNMPv2c and SNMPv3.
SNMPv2c
Parameter
Enable SNMPv2c
Read community
Write community
Trap community
System information (MIB-II, v2c/v3)
Parameter
System contact
System name
System location
PoE MIB (RFC3621, v2c/v3)
This parameter has no effect on actual VLAN traffic. The management uplink port assists the
unit to evaluate if the new VLAN configuration might block the unit from being managed
over VLAN from this port. If a possible conflict is detected, an error message appears and the
new VLAN configuration is rejected.
Configure which VLAN ID to be used when managing the unit whenever VLAN is enabled.
Description
Set VLAN mode to Access or Trunk for each of the Ethernet ports.
Access — VLAN is used only inside the unit to split or limit packet access to specific ports
only. Any incoming VLAN tagged packets received by VLAN access port is discarded. VLAN
tagging is added to the unit packet for VLAN Access incoming packets. Unit internal VLAN
tagging is stripped out for VLAN Access outgoing packets.
Trunk — All Ethernet packets are VLAN tagged. Any untagged VLAN packets received by
VLAN trunk port is discarded.
Configure the VLAN ID to be used whenever the port is configured as Access. The unit
internal management port acts as access only. It can only be reached from a single
management VLAN ID.
Configure the VLAN Trunk port as filtered or unfiltered.
Enabled — Only data flow from some VLAN IDs, specified in the Trunk VLANs list, passes
through VLAN Trunk port. All other VLAN tagged traffic is discarded.
Disabled — Data flow from all VLAN IDs passes through VLAN Trunk port.
List the VLAN IDs that may pass through VLAN Trunk port whenever TRUNK – Filter
unknown VLAN is enabled.
Description
Enable or disable SNMPv2c support.
Configure the SNMPv2c GET community string. Example: public.
Configure the SNMPv2c SET community string. Example: private.
Configure the SNMPv2c Trap community string. Example: public.
Description
Configure the SNMP MIB-II system contact OiD string. Example: John.
Configure the SNMP MIB-II system name. Example: My Unit.
Configure the SNMP MIB-II system location. Example: University.
12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents