IUH-F117-V1-*
Operation
Byte position
[10]
[11]
[12]
[13]
[14]
[15]
Antenna Polarization AP
This parameter switches polarization to linear/circular or reads out the currently
set polarization.
ParamTyp:
Default
Value range:
Example:
WP1UAP.00.01L switches the polarization to linear
WP1UAP.00.01C switches the polarization to circular
RP1UAP.00.00 reads out the set polarization
Set the polarization according to the read/write tag used (see chapter 5.3.3).
Higher sensitivity if both the read/write head and the read/write tag are
polarized linearly.
There are gaps in the detection range if the read/write head is polarized
linearly.
Power Transmit PT
This parameter sets the transmission power in mW or reads out the set
transmission power.
The transmission power is stated for IUH-F117-V1-EU and IUH-F117-V1-CN in
W
. The transmission power is stated in W for the read/write head IUH-F117-
erp
V1-US
eirp
ParamTyp:
Default:
Value range:
Example:
WP1UPT.00.02.00.64 sets 100 mW
WP1UPT.00.02.07.D0 sets 2000 mW
RP1UPT.00.00 reads out the set transmission power
Meaning
TA parameter
E5 parameter
AP parameter
AC parameter
QV parameter
MB parameter
AP
AP = C
L, C
.
PT
PT = .07.D0
= 2000 mW
bin
100–2000 mW
erp
100–4000 mW
eirp
Value range
See "Tries Allowed TA" on page 39
See "Enhanced Status 5 E5" on page 39
See "Antenna Polarization AP" on page 37
See "Anti-Collision AC" on page 38
See "Q-Value QV" on page 39
See "Memory Bank MB" on page 40