Pepperl+Fuchs IUH-F117-V1-EU Manual page 28

R/w head for identcontrol
Hide thumbs Also See for IUH-F117-V1-EU:
Table of Contents

Advertisement

IUH-F117-V1-*
Commissioning
Note!
The device makes no distinction between commands entered in upper and lower
case. Make sure that there are no spaces in all parameters that come after the
command.
Example:
In the examples below, the read/write head is connected to channel 1 of the
control interface.
The control interface must be connected to an RS 232 interface.
Reading Tags
Set the tag type to IUC80. Do this by transmitting the command change tag (see
"Change Read/Write tag CT" on page 34) to the read/write head. Once you have
set this general tag type, all tags can only be addressed via the read/write
commands single read fixcode and enhanced read fixcode (see "Single read
fixcode SF" on page 31 and see "Enhanced read fixcode (EF)" on page 31) .
Change Read/Write Tag
Command:
Confirmation:
Response:
Transmit the command enhanced read fixcode to the read/write head. The LEDs
on the read/write head flash green.
Enhanced Read Read-Only Code
Command:
Confirmation:
Response:
Table 6.1
Move a IUC* tag into the read/write head's detection range. When the tag is
detected and the read-only code is read out, the LED on the read/write head turns
yellow. The read-only code is displayed in the terminal program.
28
Serial
CT180
-
01
Serial
EF1
-
51
No tag in the detection range
Ethernet
PROFIBUS
.00.06.04.02.38.30
.04.02.38.30
.00.06.04.02.FF.09
.04.02.FF.09
.00.06.04.02.00.0A
.04.02.00.0A
Ethernet
PROFIBUS
.00.04.1D.03
.1D.03
.00.06.1D.03.FF.0B
.1D.03.FF.0B
.00.06.1D.03.05.0C
.1D.03.05.0C

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iuh-f117-v1-usIuh-f117-v1-cn

Table of Contents