IUH-F117-V1-*

Commissioning

6
Commissioning
6.1

Connection

Caution!
Uncontrollable triggered processes
The plant where the device is installed may be damaged.
Before commissioning, make sure that all processes run in a controlled manner.
Warning!
Incorrect electrical connection
Damage to the device or system caused by incorrect electrical connection
Check all connections in the plant before commissioning the device.
When you connect the control interface to the power supply, the PWR/ERR LED
on the device lights up green. If the LED on the device does not light up, the power
supply is connected incorrectly. The LED on the device lights up red when a
device fault occurs. If the PWR/ERR LED flashes red and green alternately after
you connect the IUH-F117-V1 read/write head, the power supply does not offer
sufficient power. If the LED on the read/write head slowly flashes green, the
control interface is configured incorrectly.
6.2

Device settings

Caution!
Device not configured or configured incorrectly
System failure caused by incorrectly configured device
Configure the device prior to commissioning.
You must configure the control interface before commissioning the read/write
head. Read the chapter "Commissioning" in the manual accompanying your
control interface.
Configure the R/W heads with the described system commands.see chapter
7.3.2). To view an example of parameterization see chapter 6.3.
6.3

Operating via the Command Interface

This section shows you how to operate the IUH-F117-V1-* read/write head using
an IDENTControl Compact control interface with serial interface. The
commissioning procedure described relates to the RS 232 interface and involves
a PC. The examples also include the syntax for coding the commands and
parameters via the Ethernet TCP/IP and PROFIBUS interface. Further details
about these codes and the factory setting for your IDENTControl control interface
can be found in the manual.
26