RB SERIES ENGINEERING GUIDE
Model Nomenclature
1-2
3
4
5-7
RB
RB
S
S
V
036
Model Type
ype
RB – RB Series
RB Serie
es
e
s
Operation Range
on Rang
ge
g
e
S – Single Stage
ngle Stag
g
g
ge
Cabinet Configuration
Configu
u
u
rat
at
tion
V – Vertical
rtical
H - Horizontal
rizontal
Unit Capacity (MBTUH)
pacity (M
M
M
MBT
TUH)
T
006, 009, 012, 015,
9, 012, 0
01
0
15
,
,
018, 024, 030, 036,
24, 030,
03
0
6
6,
041* (Vertical)
Vertical)
042, 048, 060, 070
48, 060,
07
0
0
0
Discharge Configuration
ge Conf
f
fi
gu
uration
u
T – Top (Vertical)
p (Vertic
ca
c
al)
E – End (Horizontal)
d (Horiz
zo
z
ont
t
tal)
S – Side (Horizontal)
de (Horiz
zo
z
on
tal)
t
Return Air Configuration
Air Conf
fi
f
gu
u
uration
L – Left
ft
R – Right
ght
Voltage
0 – 208-230/60/1
0
0/
/1
2 – 265-277/60/1 (018-036)
0
0/
/1
(018-036)
3 – 208-230/60/3 (024-070)
0/
0
/3
(024-070)
4 – 460/60/3 (024-070)
02
0
24
4-
-070)
5 – 575/60/3 (PSC Only 042-070)
P
P
SC
C
C Only 042-070)
9 – 115/60/1 (006-012)
00
0
06
6-
-012)
Future Option
0 – None
Blower Options
s
0 – PSC Blower
er
1 – Variable Speed ECM Blower (015-070)
pee
e
ed ECM Blower (015-070)
4 – 5-Speed ECM Blower (015-070)
CM
M
M Blower (015-070)
Water Coil Option
on
C – Copper
N – CuproNickel
kel
Sound Kit Option
on
A – None
B – Sound Kit (Not Available on H006-012)
(Not Available on H006-012)
Future Option
N – None
Note: Phase Guard Only Available on 208-230/60/3 and 460/60/3
50VA Transformer with Aurora and 75VA Transformer with SMART Equipment
Waterside economizer option must be ordered with stainless steel drain pan and either 5-speed ECM or variable speed ECM (024-070)
*2 way valve, water flow regulator, economizer, disconnect, 2" filter and filter rack not available in RBSV041.
8
9
10
11
12
13
14
T
L
0
0
0
C
A
All RB Series product is safety listed under UL1995 thru ETL and performance listed with AHRI in
accordance with standard 13256-1.
15
16
17
18
19
20
21
N
N
A
5
N
0
0
4
22-23
24
SS
*
V
Vintage
* – Factory Use Only
Non-Standard Options
N
SS – Standard
SA – Split Access Panel
SB – Service Ports located to the front of the unit
SD – Split Access Panel and Service Ports located to
t
the front of the unit
Drain Pan Option
D
0 – Composite, No Secondary Connection
1 – Composite, Secondary Connection
2 – Stainless Steel, No Secondary Connection
3 – Stainless Steel, Secondary Connection
Cabinet Option
C
0 – Unpainted, 1 in MERV 4, Filter Rail
1 – Painted, 1 in MERV 4, Filter Rail
2 – Unpainted, 2 in MERV 13, Filter Rail
3 – Painted, 2 in MERV 13, Filter Rail
4 – Unpainted, 1 in MERV 4, Filter Rack
5 – Painted, 1 in MERV 4, Filter Rack
6 – Unpainted, 2 in MERV 13, Filter Rack
7 – Painted, 2 in MERV 13, Filter Rack
Electrical Option
E
N – No Phase Guard, No Disconnect
D – No Phase Guard, Disconnect
P – Phase Guard, No Disconnect
B – Phase Guard, Disconnect
A
Air Coil Option
5 – All-Aluminum, AlumiSeal
6 – All-Aluminum, AlumiSeal, Standard Range
7 – All-Aluminum, No Coating, Extended Range
8 – All-Aluminum, No Coating, Standard Range
C
Control Option
TM
A – Aurora
Base Control (ABC)
TM
Z – Aurora
with SMART Equipment DDC
W
Water Control Option
W
W
N – None
R – Water Flow Regulator (015-070)
V – 2-Way Valve (015-070)
B – 2-Way Valve w/ Water Flow Regulator (015-070)
W – Waterside Economizer
S – Waterside Economizer w/ Water
Flow Regulator
E – Waterside Economizer w/ 2-Way Valve
C – Waterside Economizer w/ 2-Way Valve &
Water Flow Regulator
TM
, Extended Range
Need help?
Do you have a question about the RBS009 and is the answer not in the manual?