Approvals And Certifications; Disposal - Danfoss VLT Midi Drive FC 280 Instruction Manual

Adjustable frequency drive
Hide thumbs Also See for VLT Midi Drive FC 280:
Table of Contents

Advertisement

Introduction
1
1
Area
1
Line power input
2
Rectifier
3
DC bus
4
DC reactor
5
Capacitor bank
6
Inverter
7
Output to motor
8
Control circuitry
Table 1.2 Legend to Figure 1.1
1.4.3 Enclosure Sizes and Power Ratings
For enclosure sizes and power ratings of the adjustable
frequency drives, refer to chapter 9.9 Enclosure Sizes, Power
Ratings and Dimensions.
4
Component
Functions
AC line power supply to the
adjustable frequency drive.
The rectifier bridge converts
the AC input to DC current to
supply inverter power.
Intermediate DC bus circuit
handles the DC current.
Filters the intermediate DC
circuit current.
Provides line transient
protection.
Reduces the root mean square
(RMS) current.
Raises the power factor
reflected back to the line.
Reduces harmonics on the AC
input.
Stores the DC power.
Provides ride-through
protection for short power
losses.
Converts the DC into a
controlled PWM AC waveform
for a controlled variable
output to the motor.
Regulated 3-phase output
power to the motor.
Input power, internal
processing, output and motor
current are monitored to
provide efficient operation
and control.
User interface and external
commands are monitored and
performed.
Status output and control can
be provided.
Danfoss A/S © 11/2015 All rights reserved.
®
VLT
Midi Drive FC 280
1.4.4 Safe Torque Off (STO)
®
The VLT
supports Safe Torque Off (STO). See chapter 9.9 Enclosure
Sizes, Power Ratings and Dimensions for details about the
installation, commissioning, maintenance and technical
data of STO.

1.5 Approvals and Certifications

For compliance with the European Agreement concerning
International Carriage of Dangerous Goods by Inland
Waterways (ADN), refer to ADN-compliant Installation in the
®
VLT
Midi Drive FC 280 Design Guide.
Applied standards and compliance for STO
Use of STO on terminals 37 and 38 requires that the user
satisfies all provisions for safety including relevant laws,
regulations and guidelines. The integrated STO function
complies with the following standards:

1.6 Disposal

Midi Drive FC 280 adjustable frequency drive
IEC/EN 61508: 2010 SIL 2
IEC/EN 61800-5-2: 2007 SIL2
IEC/EN 62061: 2012 SILCL of SIL2
EN ISO 13849-1: 2008 Category 3 PL d
Do not dispose of equipment containing
electrical components together with
domestic waste.
Collect it separately in accordance with
local and currently valid legislation.