3.7

Installation of the machine

Connection
Electrical connection
The machine has only one external electrical connection.
DANGER
1.
Assemble a power handle switch ON/OFF on the main wall socket. The handle switch
ON/OFF must be positioned at a height of 0,6 - 1.9 meters from the floor. The preferred
height is 1,7 meters. The handle switch must be red and the back ground around it
yellow.
2.
Make sure the external electrical supply cables is sectioned.
Make sure the main switch on the machine is in "0" position and locked with a lock.
3.
NOTE
3.8

Machine testing

Before the delivery from our factory, the following tests are carried out:
• General adjustments of the machine and auxiliary functions.
• Trials to determine the good efficient functioning of the general adjustments and
correct rotation of the motors.
• Trials to determine the efficient performance of the guarding and emergency's.
Verify about the correct motor rotatin
Before the machine is put into operation, make sure the air and electrical connections
have been carried out correctly.
1.
Give current to the machine by turning the main switch (IG) to position 1
2.
Make sure the wire cut motor turns in the direction of the yellow arrow (see
Rotating direction of the wire cut motor..
direction invert two wires (phases) on the main terminal, reference L1/L2/l3
DANGER
Control to determine the efficiency of the safety devices
Before starting production, it is recommended to control the safety's devices as follows:
1.
1. Efficiency of the emergency stop button ( a page 14); ); Whilst the machine is
running push the emergency stop button on the main control panel; The machine
page 28
Make sure the electrical supply is according to the machine pecifications
and requirements.
Respect the voltage shown on the adhesive placed just above the machine
socket.
The inversion of two power supply phases must be done with the machine
disconnected from the power supply mains.
. a pag. 29); If the direction in the wrong
Machine Characteristics
Fig. 3.3
Bisky