3.6

Error Code List

The following table shows the codes for errors occurred in a C intelligent function module.
Error code
Error name
1800H
User function not registered
1801H
ROM write count error
1805H
Program fault
1806H
Program fault
1807H
IP Filter error
1808H
The number of data points
out of range error
1809H
Sampling cycle out of range
error
180AH
Filter type out of range error
180BH
Cutoff frequency 1 out of
range
180CH
Cutoff frequency 2 out of
range
180DH
Digital filter type out of range
error
180EH
Degree out of range error
180FH
Ripple out of range error
1810H
Digital filter operation error
1811H
The start address of input
data storage destination out
of range error
1812H
The start address of output
data out of range error
1813H
Selected waveform data type
out of range error
1814H
The number of sampling
points out of range error
1815H
Setting value of the window
function out of range error
1816H
Setting value of an output
spectrum format out of range
error
1817H
FFT operation error
1818H
Standard value out of range
3 TROUBLESHOOTING
60
3.6 Error Code List
Description
G(P).CEXECUTE was executed without
registering a routine by
CITL_EntryDedicatedInstFunc function.
The number of writes to the ROM exceeded
100000 times. (Number of writes > 100000)
The request data length of G(P).CEXECUTE is
out of range.
The response data length of G(P).CEXECUTE is
out of range.
IP filter function is not working properly. Setting
the target IP address is duplicated.
The specified value of the specified number of
data points is out of the range.
The specified value of the specified sampling
cycle is out of the range.
The specified filter type is out of the range.
The specified value of the cutoff frequency 1 is out
of the range.
The specified value of the cutoff frequency 2 is out
of the range.
The specified value of the digital filter type is out of
the range.
The specified value of the degree is out of the
range.
The specified value of the ripple is out of the
range.
The specified value of degree is larger than the
number of data.
• The specified value of the start address of input
data storage destination is out of the range.
• The specified value of the start address of input
data storage destination + number of data
points to be stored to the buffer memory, which
was specified for the start address of input data
storage destination, is out of the range.
• The specified value of start address of output
data is out of the range.
• The specified value of the start address of
output data + number of data points stored in
the buffer memory specified for the start
address of output data is out of the range.
The specified value of selected wave data type is
out of the range.
The specified value of the specified number of
sampling points is out of the range.
The specified value of the specified window
function is out of the range.
The specified value of the output spectrum format
is out of the range.
Unavailable data for FFT operation is specified.
The specified value of the reference value is out of
range.
Corrective Action
Execute CITL_EntryDedicatedInstFunc function
and register a routine before G(P).CEXECUTE
executing.
Replace the C intelligent function module.
Check the request data length of
G(P).CEXECUTE.
Check the response data length of
G(P).CEXECUTE.
Please set so as not to overlap the target IP
address.
Check if a value within the settable range is stored
for the number of data points.
Specify 1 to 1,000,000 for sampling cycle.
Specify 0 to 3 for frequency response filter type.
Cutoff frequency 1 is set to 0 or less, or the
sampling frequency / 2 or more is set.
Please reconsider the set value.
Cutoff frequency 2 is set to 0 or less, sampling
frequency / 2 or more, or cutoff frequency 1 or
less. Please reconsider the set value.
Specify 0 to 2 for digital filter type.
Check if a value within the settable range is stored
for the degree.
Specify 0.015625 to 1.0 for Ripple.
Check if the value of degree is less than the
number of data.
• Check if a value within the settable range is
stored for the start address of input data storage
destination.
• Check the value of the specified start address of
input data storage destination + number of data
points to be stored to the buffer memory, which
was specified for the start address of input data
storage destination.
• Check if a value within the settable range is
stored for the start address of output data.
• Check the specified value of the start address of
output data + number of data points stored in
the buffer memory specified for the start
address of output data.
Check if a value within the settable range is stored
for the waveform data type selection.
Specify 64, 128, 256, 512, 1024, 2048, 4096,
8192, 16384, 32768 for the number of sampling
points.
Specify 0 to 3 for the value of the window function.
Specify 0 to 2 for the output spectrum format.
Check if the data that can be calculated by FFT is
specified.
Specify 1 to 1,000,000 as the reference value.