Vacon X5EIP01 Installation Manual
Vacon X5EIP01 Installation Manual

Vacon X5EIP01 Installation Manual

Ethernet ip option board with 115 vac encoder interface, x series

Advertisement

Quick Links

X5EIP01 Ethernet IP Option Board with
115 VAC Encoder Interface
Installation Manual
DPD00111
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Advertisement

loading

Summary of Contents for Vacon X5EIP01

  • Page 1 X5EIP01 Ethernet IP Option Board with 115 VAC Encoder Interface Installation Manual DPD00111 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com...
  • Page 2 Administrator. Overlapping IP addresses cause conflicts between devices. The X5EIP01 also provides the option of controlling the X5 AC drive from 115 VAC control signals, or of connecting a shaft-mounted encoder to the drive to improve speed regulation. Up to five channels of 115 VAC control are available for use in selecting direction, preset speeds, or other drive functions.
  • Page 3: Ethernet Connector

    X5EIP01 Ethernet IP with 115 VAC / Encoder Interface Option Board vacon DANGER HAZARDOUS VOLTAGE • Disconnect all power before servicing a drive unit or its components. WAIT 5 MINUTES until the DC bus capacitors discharge. • Ensure that any other power sources that may feed control logic have been disconnected.
  • Page 4 X5EIP01 Ethernet IP with 115 VAC / Encoder Interface Option Board vacon Before you can install the option board, you must first remove the drive cover. Figure 2 shows the locations of the cover screws. The torque range for the X5 Size 1 cover is 18-26 in/lbs.
  • Page 5 X5EIP01 Ethernet IP with 115 VAC / Encoder Interface Option Board vacon Next, install the flexible circuit to finish the interface to the control board. (Refer to Figure 4.) To install the flexible circuit, first remove the keypad frame (necessary in this size unit). The frame is attached with two screws in opposite corners;...
  • Page 6 X5EIP01 Ethernet IP with 115 VAC / Encoder Interface Option Board vacon Table 1: Encoder Interface Terminals Terminal Description 115 VAC logic input; connect input to 115 VAC to activate. DI-A The programmable functionality of these inputs is controlled by DI-B parameters 728, 729, 730, 731, and 732.
  • Page 7 X5EIP01 Ethernet IP with 115 VAC / Encoder Interface Option Board vacon Specifications for Encoder / 115 VAC Interface Encoder Interface 115 VAC Interface Speed regulation < 0.1 Hz (1) On state 90-140 VAC Input frequency (max.) 100 kHz Off state <...
  • Page 8 X5EIP01 Ethernet IP with 115 VAC / Encoder Interface Option Board vacon The encoder interface can easily serve as one of the inputs to the X5’s Keeper Function (data logging). See the X5 User’s Manual for more information. Both the Vmet and Imet output from the drive can be configured to indicate the status of the encoder. Parameters 700 (Vmet) and 702 (Imet) that relate to the setup and calibration of the Vmet and Imet outputs, both have selections related to the status of the encoder input.
  • Page 9 X5EIP01 Ethernet IP with 115 VAC / Encoder Interface Option Board vacon Getting Started To begin communicating with the drive over Modbus / TCP, the drive’s IP address must be set (use parameters 922- 925). After setting the IP address, cycle power off and on for the new address to take effect.
  • Page 10 X5EIP01 Ethernet IP with 115 VAC / Encoder Interface Option Board vacon Example 1: Output Assemblies Instance Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Fault Reset Run Fwd Speed Reference (low byte)
  • Page 11 X5EIP01 Ethernet IP with 115 VAC / Encoder Interface Option Board vacon Example 2: Input Assemblies Instance Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Running 1 (Fwd) Faulted Speed Actual (low byte)
  • Page 12 X5EIP01 Ethernet IP with 115 VAC / Encoder Interface Option Board vacon Control Supervisor Behavior The State Transition diagram in Figure 7 provides a graphical description of the states and corresponding state transitions for the control supervisor. Figure 7: Control Supervisor State Transition Diagram Table 6 on page 14 explains the state transitions pictured in the flow diagram in Figure 7.
  • Page 13 X5EIP01 Ethernet IP with 115 VAC / Encoder Interface Option Board vacon Table 6: Explanation of State Transitions (Page 1 of 2) Input Conditions Results Old State Event New State Action Power_Off NonExist Faulted = 0 Ready = 0 FwdMode = 0...
  • Page 14 X5EIP01 Ethernet IP with 115 VAC / Encoder Interface Option Board vacon Table 6: Explanation of State Transitions (Page 2 of 2) Input Conditions Results Old State Event New State Action Faulted = 1 FaultCode = x (Initiate Faulted Stop)
  • Page 15 X5EIP01 Ethernet IP with 115 VAC / Encoder Interface Option Board vacon List of Object Classes The Communication Interface supports the following object classes: Table 7: Object Classes Class Object 0x28 Motor Data 0x29 Control Supervisor 0x2A AC/DC Drive 0x2B...
  • Page 16 X5EIP01 Ethernet IP with 115 VAC / Encoder Interface Option Board vacon Ethernet Troubleshooting Following are the advanced fault codes for the drive fault (F38) related to the option board. For more information, see the X5 User’s Manual (Chapter 8). The...
  • Page 17 X5EIP01 Ethernet IP with 115 VAC / Encoder Interface Option Board vacon Appendix: X5 Communication Interface Object Profiles In the following tables, attributes shown in bold face are stored in the non-volatile part of the drive and maintain their values after a power loss. All other settable attributes will power up at their default values.
  • Page 18 X5EIP01 Ethernet IP with 115 VAC / Encoder Interface Option Board vacon Table 11: Control Supervisor Object (Class Code 0x29, Control Supervisor Class (41) - Instance Attributes (1) Default, Data Attribute Name Services Minimum, Description Type Maximum Get_Attribute_Single Run1 Run Forward Request...
  • Page 19 X5EIP01 Ethernet IP with 115 VAC / Encoder Interface Option Board vacon Table 12: AC/DC Drive Object (Class Code 0x2A, AC/DC Drive Class (42) - Instance Attributes (1) Default, Data Attribute Name Services Minimum, Description Type Maximum AtReference Get_Attribute_Single 1 = Drive actual at speed reference...
  • Page 20 X5EIP01 Ethernet IP with 115 VAC / Encoder Interface Option Board vacon Table 13: Parameter Object (Class Code 0x65, Parameter Class (101) - Class Attributes (1-999) Default, Data Attribute Name Services Minimum, Description Type Maximum These instances give direct access to...