Checking Before Use; Remove The Apparatus; Cleaning And Disinfecting - INTERSPIRO 90U User Manual

S-mask
Hide thumbs Also See for 90U:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
ENGLISH
5

CHECKING BEFORE USE

Check that the cylinder has sufficient pressure.
1.
Hold your breath and check that no airflow is heard.
2.
Put two fingers between the sealing edge and face and check that a strong
3.
airflow is heard.
6

REMOVE THE APPARATUS

Switch off the positive pressure, see section 2.
1.
Open the buckles to release the head harness, loosen strap and remove the face
2.
mask.
Close the cylinder valve.
3.
Unfasten the waist belt buckle and loosen the shoulder straps.
4.
Remove the apparatus and activate the positive pressure to purge air from the
5.
system.
7

CLEANING AND DISINFECTING

Clean and disinfect as necessary after use.
Open the cylinder valve and check that there is pressure in the system before
1.
cleaning.
NOTE: HAVING THE CYLINDER VALVE OPEN PREVENTS WATER FROM ENTERING THE SYSTEM AND BUBBLES
WILL INDICATE ANY LEAKS IN THE SYSTEM.
Place the apparatus except face mask and breathing valve, pressure gauge and
2.
warning whistle into clean water.
Clean the apparatus with a brush and Curacid PSA Rinse or equivalent.
3.
Rinse the apparatus in clean water.
4.
Dry the apparatus and close the cylinder valve. Activate positive pressure to purge
5.
air from the system.
FACE MASK
Disconnect the breathing valve as described in section 3.
1.
Wash the face mask in lukewarm water (maximum 40° C) with Curacid PSA Rinse
2.
or equivalent.