Updating Bmc Firmware - NEC EXP320R Maintenance Manual

Nec express server express5800 series vmware
Hide thumbs Also See for EXP320R:
Table of Contents

Advertisement

Chapter 1 Maintenance

4.3.6 Updating BMC firmware

Use the following command to update the BMC firmware.
# /opt/ft/bin/ftsmaint burnBmcs fw_file
1. Login to ftSys Management Appliance as a root user.
2. Use the SCP command or Host Client to store the BMC firmware file in the desired directory of ftSys
Management Appliance.
In the example below, ft control software Install DVD is mounted and BMC firmware file is copied to ftSys
Management Appliance.
# cp /mnt/cdrom/firmware/bmc/2800_4800_6800/062-03711bmc_bnn.nnrnn.nnsnn.
nn.bin/opt/ft/firmware/bmc/2800_4800_6800
3. Run the following command to check the State shows "ONLINE" and Op State shows "DUPLEX" for I/O
modules 0 and 1.
# /opt/ft/bin/ftsmaint ls 10
H/W Path
...
State
Op State
...
# /opt/ft/bin/ftsmaint ls 11
H/W Path
...
State
Op State
...
4. Run the following command to check the State shows "ONLINE" and Op State shows "DUPLEX" for
BMCs of I/O modules 0 and 1.
# /opt/ft/bin/ftsmaint ls 10/120
H/W Path
...
State
Op State
......
# /opt/ft/bin/ftsmaint ls 11/120
H/W Path
...
State
Op State
......
Express5800/R320e-E4, R320e-M4, R320f-E4, R320f-M4 Maintenance Guide (VMware)
34
Important
Shutdown the guest OS except for ftSys Management Appliance.
Tips
See Chapter 2 (1.1.2 Install NEC ESMPRO Agent) in Installation Guide for how to
mount/unmount ft control software Install DVD.
: 10
: ONLINE
: DUPLEX
: 11
: ONLINE
: DUPLEX
: 10/120
: ONLINE
: DUPLEX
: 11/120
: ONLINE
: DUPLEX
4. Maintenance of Express5800/ft series