Chapter 3 Useful Features
Option
Thermal Sensor
POST Error Pause
Display BMC IP address in
POST
Legacy memory copy
Express5800/R320e-E4, R320e-M4, R320f-E4, R320f-M4 Maintenance Guide (VMware)
174
Parameter
Disabled
Enable or disable the feature to monitor the thermal sensor.
[Enabled]
[Disabled]
Set whether to stop POST temporarily at the end of POST
Enabled
when an error occurs during execution of POST.
Disabled
Enable or disable the feature to display BMC IP address
[Enabled]
during POST. (This option is indicated only by R320f-M4
and R320f-E4.)
Disabled
Specify the memory copying method to other module. Don't
Enabled
change this option when there are no directions. (The
factory setting differs depending on the environment you
are using. Also, this option may not be displayed.)
- When R320e-M4, R320e-E4 model
Factory settings is [Enabled].
This option is different in setting depending on ESXi
Version.
1) If ESXi Version is ESXi6.0
Don't change the setting.
2) If ESXi Version is ESXi6.5 or more
Change to [Disabled] setting.
Confirm the BIOS version. If BIOS version is not
8.1:71 or more, update to most new version.
Then change to setting.
See Chapter 1 Installing OS in Installation Guide,
and change the setting.
- When R320f-M4, R320f-E4 model
Factory settings is [Disabled].
Don't change the setting.
Descriptions
[
]: Factory settings
1. System BIOS