9 CONFIGURATION MENU
9.2.1
Forget override
Place the cursor on the REMOTE CONTROLS row. Press ENTER to bring up a list of
alternatives.
With FORGET OVERRIDE in the "ON" position, the most recently recalled memory is
automatically recalled before each new welding start. This is to eliminate the results of all
weld data settings produced during the most recent welding procedure.
9.2.2
Configuration for digital remote control unit
Without remote control adapter
When connecting a CAN-based remote control unit, configuration takes place automatically,
DIGITAL OP.
With remote control adapter
When using a digital remote control unit, specify which type of remote control unit is being
used.
Position the cursor on the DIGITAL OP row and press ENTER to bring up of list, from which
you can select an alternative.
BINARY CODED
10-PROGR
* or Welding gun with RS3 program selection
9.2.3
Configuration for analogue remote control unit
Without remote control adapter
When connecting a CAN-based remote control unit, configuration of ANALOG 1 and
ANALOG 2 takes place automatically. The configuration cannot be altered.
With remote control adapter
With remote control adapter When you use an analogue remote control unit, you can specify
on the control panel which (maximum 2) potentiometer(s) you want to use.
The potentiometers are called ANALOG 1 and ANALOG 2 in the control panel and refer to
their own set parameters for the welding process, e.g. wire feed parameter (ANALOG 1) and
voltage parameter (ANALOG 2) with MIG/MAG.
0460 896 274
•
32-program unit
•
10-program unit *