MultiBio 700 Installation Guide
1. Equiment Installation
MultiBio 700 Mounting Paper
(only for your reference)
In st ru ct io n fo r th e Mo un ti ng P ap er
Be fo re t he d ev ic e is f as te ne d, p le as e st ic k th e pa pe r t o t he p la ce w he r e y ou
wa nt t o in st al l it , th en m ak e ho le s an d
la y ca bl es a cc or di ng t o th e mo un ti ng pa pe r.
Wiring Hole
10
11
12
(1) Post the mounting template on the
(2) Remove the screw on the bottom
wall.Drill the holes according to
of device.
the marks on the template (holes
for screw and wiring).
(4) Fix the back plate on the wall
(5) Fix the device to the back plate.
according to the mounting paper.
2. Structure and Function
RS485
TCP/IP
RS232/RS485 Converter
Exit Button
EXIT BUTTON
Lock Sensor

Door Bell External Reader
Alarm
Version: V1.1 Date: Nov. 2011
(3) Take away the back plate.
Access Control System Function
(1) If a registered user verified, the device will
export the signal
to unlock the door.
(2) Door sensor will detect the on-off state. If the door is un-
expected opened or improperly closed, the alarm signal
(digital value) will be triggered.
(3) As the d evice is removed illegally , it will output an alarm signal.
(4) External card reader is supported.
(5) External exit button is supported, it is convenient to open the
door inside.
(6) External door bell is supported.
(7) Supports RS485 , TCP/IP modes
to connect with PC. One PC can
manage multiple devices.
3.Lock Connection
(1) Shares power with the lock:
+
+12V
-
GND
BELL-
DC12V
BELL+
DC12V
SEN
GND
NO LOCK
BUT
NC LOCK
-
NO
COM
FR 107
+
NC
AL+
AL-
(2) Does not share power with the lock:
+
+12V
-
GND
DC12V
DC12V
BELL-
BELL+
+
SEN
GND
NO LOCK
-
BUT
DC power
NO
COM
+
NC
AL+
FR 107
AL-
DC power
NC LOCK
(1) The system supporst NO LOCK and NC LOCK. For example the NO LOCK (normally open at power on) is connected
with 'NO' terminal, and the NC LOCK is connected with 'NC' terminal.
(2) When the Electrical Lock is connected to the Access Cont rol System, you need to parallel one FR107 diode (equipped
in the package) to prevent the self-inductance EMF affecting the system, do not reverse the polarities.
4. Connected with other parts:
BELL-
BELL+
Door Bell

SEN
GND
BUT
EXIT BUTTON
NO
Exit Button
COM
NC
Alarm Power
AL+
Door Sensor
Alarm
AL-
+
-
Voltage output ≤ DC 12V for Alarm
①:'I': device output current, ' U
I
LOCK
LOCK
Warning: No operating with power on
+
+12V
GND
-
Device shares power with the lock:
BELL-
BELL+
>1A...... ①
U
=12V, I-I
LOCK
LOCK
SEN
-
GND
And the lock is near to the device.
BUT
FR 107
NO
+
COM
NC
AL+
AL-
+
+12V
-
GND
Device does not shares power with the lock:
-
BELL-
A. U
=12V I-I
LOCK
BELL+
FR 107
SEN
≠12V;
B . U
+
LOCK
GND
BUT
-
C. The lock is far apart from the device.
NO
COM
+
NC
AL+
AL-
5. Connected with Power:
Input DC 12V, 500mA (50mA standby)
Positive is connected with '+12V', negative is connected
with 'GND' (do not reverse the polarities).
+
+12V
-
GND
DC12V
': lock voltage,' ': lock current
≤ 1A;
LOCK

Advertisement

loading

Summary of Contents for ZKTeco MultiBio 700

  • Page 1 ! MultiBio 700 Installation Guide Warning: No operating with power on Version: V1.1 Date: Nov. 2011 3.Lock Connection 1. Equiment Installation (1) Shares power with the lock: +12V +12V MultiBio 700 Mounting Paper (only for your reference) Device shares power with the lock:...
  • Page 2 ! Warning: No operating with power on 6. Wiegand Output 7. Wiegand Input (2) RS485 Mode: The device supports standard Wiegand 26 output, The device has the function of Wiegand signal input . It s upports to 485+ 485- Please use specified RS485 wire, RS485 active converter and as a reader device it has a very good compatibility.