Addressing

Fixture addresses must be
set between 1 and 512.
There are three addressing
dials on the track adapter.
To address, use a small flat
head screwdriver to move
the arrow to the desired
address number.
Each Irideon FPZ fixture must
be considered a separate
DMX device for the purpose
of DMX line-loading
calculations. The Irideon FPZ
only has an intensity
channel.
Note:
Alternative DMX Addressing Functions
Certain DMX addresses are reserved for special functions. Addresses 700 and above
can be used for setting the intensity level of the fixture. The second and third address
numbers set the intensity level. The intensity knob is ignored when using these DMX
addresses. See the following chart for examples:
DMX Address
701
710
725
799
800
4
Status LED
In this addressing example, the fixture is
No more than 32 DMX devices can be daisy-chained
together on a single run. For runs of fixtures totaling more
than 32 DMX devices, a DMX splitter will need to be used to
split the DMX runs.
When using RDM with track fixtures, ETC recommends
connecting no more than 20 fixtures on a single run.
Function
Intensity at 1%
Intensity at 10%
Intensity at 25%
Intensity at 99%
Intensity at 100%
3
3
addressed to 503.
Local Intensity
Control Knob
DMX Addressing
Dials
3
FPZ