I/O Adapter
two #2729s in the #5064/#9364 System Unit Expansion with #9329/#9330 Expansion Unit for
PCI cards. Up to three #2729s can be installed in #5065 Storage/PCI Expansion Tower.
The #2809/#2824 PCI Feature Controller or the base PCI LAN/WAN Workstation IOP in the
#5065 Storage/PCI Expansion Tower/#5066 1.8 I/O Tower is a prerequisite for the #2729.
OS/400 V4R2 or later is required for the #2729 to support the 3995 Optical Library
Dataserver.

#2740 PCI RAID Disk Unit Controller

The #2740 is functionally equivalent to the #2726 PCI RAID Disk Unit Controller. However,
the #2740 can only be located in the System Unit. It cannot be located in the System Unit
Expansion #5064/#9364. The #2740 is supported on the 9406 Models 170 and 720 only. The
#2740 supports a maximum of 10 one- or two-byte disk units. A maximum of two RAID-5
arrays are supported on one #2740. A maximum of one #2740, #2726, #2741, #2748, or
#9728 can be installed in the system unit. The #2740 does not offer support for compression.
However, if only a maximum of 10 disks are required and there is no requirement for
compression, the #2740 should be ordered.
Concurrent maintenance of disks attached to the #2740 is only supported if the disks are
mirrored or part of a RAID array. Otherwise, the #2740 offers the same support as the #2726.
Refer to "#2726 PCI RAID Disk Unit Controller Ultra SCSI" on page 264 for more information.
The #2740 requires OS/400 V4R2 or later.
#2741 PCI RAID Disk Unit Compression Controller
The #2741 is functionally equivalent to the #2726 PCI RAID Disk Unit Controller. See "#2726
PCI RAID Disk Unit Controller Ultra SCSI" on page 264 for a full description of the #2726.
The #2741 supports a maximum of 15 disk units but offers an enhancement over the #2726 in
that it supports data compression when used with OS/400 V4R3. The #2741 requires V4R2
or later of OS/400. For all new orders with V4R2 or later, the #2741 is ordered in place of the
#2726.
Concurrent maintenance of disks attached to the #2741 is only supported if the disks are
mirrored or part of a RAID array.
A maximum of one #2741, #2726, #2740, #2748, or #9728 can be installed in the system unit
and one #2741 or #2726 in the #5064/#9364 System Unit Expansion with #9329 Expansion
Unit for PCI cards. If only a maximum of 10 disks is required and there is no requirement for
compression, the #2740 can be ordered instead of #2741.