Pitco Solstice and Solstice Supreme High Efficiency Gas Fryers
Controller Operational Modes
MODE
BOIL
With control initially off, toggle
OUT
the ON/OFF switch:
ON – OFF –
ON – OFF – Then ON
This sequence must be
performed within 3 seconds.
MELT
Select MELT and then press
ON.
Melt may be bypassed by
pressing COOK.
COOK
Press COOK and then press
ON.
Automatic entry after
completed MELT cycle.
SG/SSH Series Service Manual
ENTRY
Power and HD
indicators are on. HFB
indicator flashes at 0.5
seconds rate until exit.
Same as below except
fixed heat cycle.
GAS
ELEC 4 sec 26 sec
Power indicator is on.
HD as required to
maintain Vat
temperature. HFB
indicator follows HD.
TEMPERATURE
INDICATION
Fixed at 200°F
(93°C)
No set point. HD is
suppressed if Vat is
greater than 250°F
(121°C).
ON
OFF
8 sec 22 sec
Knob setting
9
SET POINT
Press OFF to
exit.
Automatic
switch to
COOK after
temperature is
greater than
140°F (60°C)
or press OFF
to exit.
Press OFF to
exit.
EXIT
Need help?