Pitco Solstice and Solstice Supreme High Efficiency Gas Fryers
6. Check the supply gas pressure with the
manometer and compare the reading to the
Supply Gas Pressure table on page 52 to
determine what the incoming gas pressure
should be.
Supply Pressure Table
NAT
7 to 9
NOTE:
You cannot adjust the supply gas
pressure at the unit. Anything
over/under the recommended
amount should be adjusted at the
facility's main gas line.
Taking a Manifold Gas Pressure Reading
1. Unscrew and remove the gas manifold plug with
a 3/16 inch hex wrench.
2. Finger tighten the test fitting into the test port
SG/SSH Series Service Manual
LP
11 to 13
52
7. When adjustment is complete:
a. Shut off the main gas supply line
b. Disconnect manometer.
c. Remove the test fitting.
d. Apply Teflon paste to gas supply plug.
e. Reinstall gas supply plug with a 3/16 inch
hex wrench.
f.
Turn on the main gas supply line.
3. Finish tightening the test fitting using a
7/16 inch open-ended wrench.
4. Connect the manometer.
Need help?
Do you have a question about the SG Series and is the answer not in the manual?