Pitco SG Series Solstice Service Manual page 15

High efficiency gas fryers
Hide thumbs Also See for SG Series:
Table of Contents

Advertisement

Pitco Solstice and Solstice Supreme High Efficiency Gas Fryers 
 
 
5. Turn on the main gas supply line.
6. Check the supply gas pressure with the
manometer and compare the reading to the
supply gas pressure table to determine what the
incoming gas pressure should be.
Supply Pressure Table 
NAT
7 to 9
NOTE:
You cannot adjust the supply gas
pressure at the unit. Anything
over/under the recommended
amount should be adjusted at the
facility's main gas line.
7. Shut off the main gas supply line.
8. Disconnect the manometer.
9. Remove the test fitting.
 
SG/SSH Series Service Manual 
LP
11 to 13
15 
10. Apply Teflon paste to gas supply plug.
11. Reinstall gas supply plug with a 3/16 inch hex
wrench.
12. Turn on the main gas supply line.

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SG Series and is the answer not in the manual?

This manual is also suitable for:

Ssh series

Table of Contents

Save PDF