Parameters; Parameter Overview - Danfoss 101N0715 Operating Instructions Manual

Bd controller 24 v dc with tool4cool labedition software, 101n07 series
Hide thumbs Also See for 101N0715:
Table of Contents

Advertisement

4
TOOL
COOL
®
BD Controller
101N07xx Series
24 V DC
4.1 Parameter
Overview
Parameter Group
Parameter
Main functions
Main switch
Battery
Battery cutout level
protection
Battery cutin diff.
Cutout delay
Cut-in level
Supply voltage
Compressor
Requested speed
Start delay
Start speed
Start time
Compressor speed
Condenser fan
Cond. Fan voltage
Fan speed
Fan start delay
Fan stop delay
Fan forced ON
Detect missing fan
Fan speed
Evaporator fan
Evap. Fan voltage
Fan speed
Fan start delay
Fan stop delay
Fan forced ON
Detect missing fan
Fan speed

4. Parameters

The user can change settings and observe real-time measurements (read-only)
in the following parameters.
The table in 4.1 Parameter Overview is intended for easy reference.
For more detail, please refer to 4.2 Description of Parameter Groups.
Description
On/Off regulation of power supply to
controller
Battery protection cut-out voltage
level
Voltage difference between battery
cut-in and cut-out
Time to cut-out when non-critical
battery protection implemented
Calculated value.
Cutin = Cutout + Diff.
Real-time voltage measured
on + & - terminals
Compressor speed and therefore
capacity definition
Time to start after
compressor is switched ON
Optional startup speed lower than
Requested speed, during the period
Start time.
Period of time elapsing after startup
of compressor until Requested speed
is reached
Real-time speed (+/- 10%)
Supply voltage to the
condenser fan.
Condenser fan speed synchronized
with compressor operation
Time to start as a function of
Thermostat
Time to stop as a function of
Thermostat
Force condenser fan continuously
ON or OFF
Detect whether condenser fan is
connected
Real-time condenser fan speed
Supply voltage to the evaporator fan.
Evaporator fan speed
synchronized with
compressor operation.
Time to fan start as a
function of Thermostat
Time to fan stop as a
function of Thermostat
Force evaporator fan
continuously ON or OFF
Detect whether evaporator fan is
connected
Real-time evaporator fan speed
DEHC.PS.100.I1.02
Default
Max value
Min value
OFF
ON
OFF
21.3
27
19
3.9
10
0.5
3
60
0
4000
4000
2500
4
240
2
2500
4000
2500
30
600
0
24
31
12
100
100
40
0
240
0
0
240
0
OFF
ON
OFF
OFF
ON
OFF
24
31
12
100
100
40
0
240
0
0
240
0
OFF
ON
OFF
OFF
ON
OFF
Step
Unit
Type
1
0.1
Volt
Setting
0.1
Volt
Setting
1
Seconds
Setting
0.1
Volt
Measurement
0.1
Volt
Measurement
100
rpm
Setting
1
Seconds
Setting
100
rpm
Setting
1
Seconds
Setting
1
rpm
Measurement
1
Volt
Setting
10
%
Setting
1
Seconds
Setting
1
Seconds
Setting
1
Setting
1
Setting
1
%
Measurement
1
Volt
Setting
10
%
Setting
1
Seconds
Setting
1
Seconds
Setting
1
Setting
1
Setting
1
%
Measurement
13