Display
OP
Open thermistor error
SH
Shorted thermistor error
AF - 1
Airflow switch closed when cycle started
AF - 2
Airflow switch failed to close after cycle
started
AF (Flashing)
Bouncing Airflow Switch
AF (Solid)
Airflow Switch Closed when Resuming
Cycle
Electronic OPL Micro Control
L and P Models with OM Control Suffix
1.
To use an Automatic Cycle, press an ON/SELECT pad.
Select HIGH, MEDIUM, MED LOW, LOW or NO HEAT
for items that should not be dried with heat. A light to the
left of the selected pad lights up.
HIGH temperature*
HIGH temperature**
MED temperature*
MED temperature**
MED LOW temperature* 145°F (63°C)
MED LOW
temperature**
Part No. 70476301ENR6
Definition
Table 21 Error Codes
185°F (85°C)
190°F (88°C)
160°F ( 71°C)
165°F ( 74°C)
155°F (68°C)
©
Published by permission of the copyright owner - DO NOT COPY or TRANSMIT
Corrective Action
•
Check thermistor. Replace if inoperative.
•
Check wiring diagram between control and thermistor.
Refer to wiring diagram for proper wiring.
•
Check control. Replace if inoperative.
•
Check thermistor. Replace if inoperative.
•
Check wiring between control and thermistor. Refer to
wiring diagram for proper wiring.
•
Check control. Replace if inoperative.
•
Check airflow switch. Replace if inoperative.
•
Check airflow switch. Replace if inoperative.
•
Check airflow switch to ensure that it is properly
aligned and securely mounted in the mounting bracket.
•
Make sure airflow switch can open and close freely.
•
Check installation and make sure there is adequate
airflow.
•
Make sure exhaust is not blocked.
•
Clean the lint screen.
•
Replace airflow switch if inoperative.
•
Allow up to 20 seconds for this condition to clear.
•
Check if airflow switch opens at end of cycle.
•
Replace airflow switch if inoperative.
LOW temperature
(025-055)
* = (025, 030)
** = (035, 055)
To use a Time Dry or Custom Cycle, refer to the Programming
Manual.
Operating Instructions
120°F (49°C)