To Connect Electrical Service To The
Tumble Dryer
The following steps outline the procedure for connecting
electrical service to the tumble dryer.
3 Phase Models – Each tumble dryer must be connected to its
own individual branch circuit breaker, not fuses, to avoid the
possibility of "single phasing" and causing premature failure
of the motor(s).
Part No. 70476301ENR6
Electric
©
Published by permission of the copyright owner - DO NOT COPY or TRANSMIT
Heat Source
Electrical service must be connected using the appropriate
permanent rigid metal conduit system.
Service conductors must be copper only.
For an existing service, determine your service voltage and
conductor amperage. Carefully review the tumble dryer serial
plate ratings and Electrical Requirements section of this manual.
If service is inadequate it must be upgraded by a qualified
electrical contractor. Never connect an improper or inadequate
service to any machine.
Electrical Requirements
Ground and Terminal
Block Locations
1.
Ground Lug
2.
Power Disconnect (Models Through
7/31/11)
3.
Power Distribution Block