Fifth Leveling Leg; Fire Suppression System (Optional Equipment); Check Local Codes And Permits; Water Requirements - Equipment Marketers GA025L Installation Operation & Maintenance

Stacked 25/30/35/45/55 pound 11.3/13.6/16/20.4/25 kilogram, starting serial no. 0602004144
Table of Contents

Advertisement

Figure 3

Fifth Leveling Leg

The stacked tumble dryer has a fifth leveling leg which is
shipped in the up position. The fifth leveling leg MUST BE
installed properly on the lower left side of the blower housing to
stabilize the tumble dryer. Refer to Figure 4 .
After leveling with the four cabinet leveling legs, lower the fifth
leveling leg so it contacts the floor, and then secure the screws.
The stacked tumble dryer has a 5th leveling leg on
the blower housing. It is very important to properly
adjust this leg. Unit is back heavy and could rock or
tip.
T467I
1
Fifth Leg
Figure 4
Part No. 70476301ENR6
CAUTION
W250R1
©
Published by permission of the copyright owner - DO NOT COPY or TRANSMIT
Fire Suppression System (Optional
Equipment)
Electrical shock can result in death or serious
injury. If the water dispensing system is activated,
do not attempt to operate the tumble dryer. If the
water dispensing system is activated, have the
tumble dryer inspected by a qualified agency before
operating the tumble dryer.

Check Local Codes and Permits

Call your local water company or the proper municipal authority
for information regarding local codes.
IMPORTANT: It is your responsibility to have
ALL plumbing connections made by a qualified
professional to assure that the plumbing is adequate
and conforms to local, state, and federal regulations
or codes.
IMPORTANT: It is the installation or owner's
responsibility to see that the necessary or required
water, water pressure, pipe size, or connections are
provided. Manufacturer assumes no responsibility
if the fire suppression system is not connected,
installed, or maintained properly.

Water Requirements

IMPORTANT: Water must be supplied to the fire
suppression system, or the fire suppression system
will not operate as intended.
Connection point to the electric water solenoid valve is a
3/4 inch (19 mm) hose. The fire suppression system equipped
tumble dryer must be supplied with a minimum water pipe
size of 1/2 inch (12.7 mm) and be provided with a minimum
of 20 psi (138 kPa) and a maximum of 120 psi (827 kPa)
of pressure at all times. Flowrate must be no less than, but
approximately 15 gallons (57 liters) per minute.
NOTE: Water pressure under 20 psi (138 kPa) will
cause low flow and water leakage at water solenoid
valve.
If the rear of the tumble dryer or the water supply is located in
an area where it will be exposed to cold/freezing temperatures,
provisions must be made to protect these water lines from
freezing.