Electrical Requirements; Wiring Diagram; Wiring For Central Pay - Equipment Marketers GA025L Installation Operation & Maintenance

Stacked 25/30/35/45/55 pound 11.3/13.6/16/20.4/25 kilogram, starting serial no. 0602004144
Table of Contents

Advertisement

Electrical Requirements

WARNING
To reduce the risk of electric shock, fire, explosion,
serious injury or death:
Disconnect electric power to the tumble dryer
before servicing.
Close gas shut-off valve to gas tumble dryer
before servicing.
Close steam valve to steam tumble dryer before
servicing.
Never start the tumble dryer with any guards/
panels removed.
Whenever ground wires are removed during
servicing, these ground wires must be
reconnected to ensure that the tumble dryer is
properly grounded.
WARNING
To reduce the risk of fire and electric shock, check
with a qualified service person for proper grounding
procedures. Improper connection of the equipment
grounding conductor may result in a risk of electric
shock.
WARNING
To reduce the risk of fire and electric shock, if
electrical supply is coming from a three phase
service, DO NOT connect a "High Leg" or "Stinger
Leg" to a single phase machine. On a three phase
machine, if there is a "High Leg" or "Stinger Leg" it
should be connected to L3.
IMPORTANT: Electrical connections must be made
by a qualified electrician using data on serial plate,
installation manuals and wiring diagram provided with
machine and according to local codes. Install a circuit
breaker as close to the tumble dryer as possible. If
more than one tumble dryer is being installed, a circuit
breaker must be provided for each.
Part No. 70476301ENR6
Electrical Requirements
W002R1
W068R1
W069
©
Published by permission of the copyright owner - DO NOT COPY or TRANSMIT
NOTE: Connect machine to an individual branch
circuit not shared with lighting or other equipment.
NOTE: 3 Phase Machines Only - Do not use fuses to
avoid the possibility of "single phasing" and causing
premature failure of the motors.
WARNING
In case of servicing (or putting the tumble dryer
out of order), disconnect the tumble dryer from the
main supply by switching off the circuit breaker.

Wiring Diagram

The wiring diagram is located in the junction or contactor box.
The wiring diagram part number is in the lower portion of the
electrical data on the serial plate.

Wiring for Central Pay

Applicable for the following control suffixes: 3K, 3L, BK, BL,
KK, KL, LK, LL, WK and WL.
System Connections
Connection to central pay systems will be made in the rear
juntion box of the tumble dryer. For stack models, connection
for both the lower control and upper control will be made in the
upper junction box.
Locate the harness with Black, Blue, Gray and Brown wires. The
upper and lower harness can be identified by a yellow label on
the harness tubing indicating "UPPER" and a white label on the
harness tubing indicating "LOWER".
The wire colors will be the same regardless of control type.
Splice the after-market central pay system wires to the tumble
dryer control wire harness as follows.
BLK wire
BLU wire
GRY wire
Electrical Requirements
W796
24V AC/DC from central
pay system
Common (negative) from
central pay system
Machine busy signal to
central pay system
63