Specific Conversion Procedures - Equipment Marketers GA025L Installation Operation & Maintenance

Stacked 25/30/35/45/55 pound 11.3/13.6/16/20.4/25 kilogram, starting serial no. 0602004144
Table of Contents

Advertisement

1
Gas Shut-Off Valve (Ahead of pressure tap) (Not
Supplied)
2
Pressure Tap
3
Gas Shut-Off Valve (Shown in closed position) (Not
Supplied)
4
Specified Local Inlet Pressure
Figure 14
How to Change Burner Orifice Size
1.
Disconnect electrical power from tumble dryer. Close gas
shut-off valve to tumble dryer. Refer to Figure 14 .
2.
Remove spud holder. Unscrew spud holder nut near gas
valve. Remove the burner orifice(s) from spud holder. Refer
to Figure 15 Models Through 12/31/13 and Figure 16
Models Starting 1/1/14 .
3.
Install the new, correct burner orifice(s). Refer to Figure 17
Burner Orifice and Table 1 . Torque each to 9 – 10 Nm.
Part No. 70476301ENR6
©
Published by permission of the copyright owner - DO NOT COPY or TRANSMIT

Specific Conversion Procedures

How to Convert Gas Valve from Regulated to
Unregulated
NOTE: Conversion from regulated to unregulated
is only needed when regulated tumble dryers were
ordered, but unregulated tumble dryers were needed.
1.
Disconnect electrical power from tumble dryer. Close gas
shut-off valve to tumble dryer. Refer to Figure 14 .
2.
Follow instructions in Conversion Kit Part No. 431485.
NOTE: These kits do not contain any burner
orifices.
3.
Replace burner orifice(s) as per Table 1
4.
If applicable, peel off the appropriate conversion sticker
(included with machine) and apply it to the serial plate over
the "ADJUSTED FOR ______ GAS: ______" information.
5.
Commission tumble dryer for use.
4.
Reinstall spud holder assembly to gas valve, making certain
burner orifice(s) are in line with burner tube opening. Refer
to Figure 17 Burner Orifice.
5.
Commission tumble dryer for use.
NOTE: Blank burner orifices are Part No. M400995.