Specifications - Martin Alien 05 User Manual

Hide thumbs Also See for Alien 05:
Table of Contents

Advertisement

A
S
PECIFICATIONS
P H Y S I C A L
Diameter of fixture at widest point:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195 mm (7.7 in)
Depth of recessed base: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118 mm (4.7 in)
Maximum protrusion of fixture from mounting surface: . . . . . . . . . . . . . . . . 65 mm (2.6 in)
Weight:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.2 kg (2.6 lbs)
S O U R C E
Lamp:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MR16, 50 W, 12 V, glass reflector
Approved models: . . . . . . . . . . . . . . . . . . . . . . . . . . Osram ENL 50W 12V custom reflector
Base: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GX 5.3
E L E C T R O M E C H A N I C A L E F F E C T S
8 color filters plus open
Speed control
C O N T R O L & P R O G R A M M I N G
Control options (via O5 Driver unit): . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DMX-512
Control options (via O5 Driver unit): . . . . . . . . . . . . . . . . . .stand-alone using DIP switches
Control options (via O5 Driver unit): . . . . . . . . . . . . . . . . dedicated operator panel - Oracle
Data input: . . . . . . . . . . CAT5 network cable (not supplied) - maximum length 10 m (33 ft)
Data output: . . . . . . . . . CAT5 network cable (not supplied) - maximum length 10 m (33 ft)
I N S T A L L A T I O N
Minimum distance to illuminated objects: . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 m (16.7 in)
Minimum clearance around air vent:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 mm (8 in)
Indoor orientation: . . . . . . . . . . . . . . . . . . . . . . . . Any (ceiling panel or wall recommended)
Maximum thickness of ceiling/wall panel: . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 mm (0.8 in)
Diameter of hole required for mounting in ceiling/wall:. . . . . . . . . . . . . . . . 182 mm (7.2 in)
D E S I G N S T A N D A R D S
EU safety: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EN 60598-2-2
T H E R M A L
Maximum ambient temperature (Ta): . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40° C (104° F)
Maximum surface temperature, steady state, Ta=40° C . . . . . . . . . . . . . . . . 90 ° C (194° F)
Cooling: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Convection cooling system
A C S U P P L Y
Alien 05 power supply: . . . . . . . . . . . . . . 12 V AC halogen lamp transformer (not supplied)
05 Driver unit power supply: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Auto-ranging

Specifications

17

Advertisement

Table of Contents
loading

Table of Contents