Ethernet

The Processing unit can output data on Ethernet from terminal
J60. In the Ethernet submenu the IP address, net mask, IP port
number and output format have to be specified. For the NMEA
format the messages GGA, GLL, VTG, HDT, ROT and RRE are
included.
IP Address:
Default setting: 192 168 001 020.
IP Net mast:
Default setting: 255 255 255 000.
IP Port#.
The IP port number, default is 5000.
Format:
Format on Ethernet line. The following
selections are available:
o NMEA
o ZDA 1 Hz. See page 24 for discription of this
format.
o STX104. A format used by service personnel
for troubleshooting the system.
o None
If "None" is selected as output format, no data will be
sent to Ethernet line.
A change in IP Address and IP Net mask parameter will not
take effect before the HS52 is restarted!