Elapsed Timer Count-Up Or Count-Down Fails To Trigger - Primex XR Levo Series Troubleshooting Manual

Digtial clock & timer, 72mhz synchronized time solution
Hide thumbs Also See for XR Levo Series:
Table of Contents

Advertisement

Elapsed Timer count-up or count-down fails to trigger

Symptom
Elapsed Timer count-up or count-down does not trigger when initiated from Timer Control Switch.
l
Problem
There may be an issue with a cable connection, wiring issue, or a defective Timer Control Switch.
Analyze
1. Inspect the Timer Control Switch for any damage or degradation.
2. Check the cable from the Elapsed Timer to the Timer Control Switch for any damage or degradation. Cable may need to be
replaced.
Levo Series Elapsed Timer: cable is a RJ11 flat telephone cable (straight wire configuration).
l
3. Loosen the screws on the membrane Timer Control Switch. The screws may be over tightened, causing the issue.
4. Swap the Timer Control Switch with a known good switch to isolate the issue to the switch itself or a potential wiring issue
between the Timer Control Switch and the Elapsed Timer.
Solution
1. Inspect Timer Control Switch.
2. Verify cable connections.
3. Loosen screwed on membrane Timer Control Switch.
4. Swap Timer Control Switch.
If the issue cannot be resolved, additional troubleshooting is required. For further assistance, contact Primex Technical Support at
1-262-729-4860.
16
XR Levo Series Digtial Clock & Timer Troubleshooting Guide