Configuration Steps - Netgear M4300-24X24F; Description; The Configuration Of The Ubex Matrix; First Steps - Lightware UBEX Installation And Network Setup Manual

Table of Contents

Advertisement

 

6. Configuration Steps - Netgear M4300-24X24F

6
C onfiguration Steps - Netgear M4300-24X24F
The following chapter describes and explains step-by-step the procedure
of the configuration for the Netgear M4300-24X24F fully managed network
switch:

Description

Î

The Configuration of the UBEX Matrix

Î

First Steps

Î
Detailed Instructions
Î
Finalizing the Matrix
Î
Installation and Network Setup Guide for UBEX
6.1. Description
This chapter helps you configure the Netgear ProSAFE
managed switch for the UBEX matrix. This model of the Netgear
contains 24x 10G SFP+ slots which are enough to serve 12 UBEX
endpoints and handle up to 24 source / destination devices. The
switch is recommended for medium businesses.
6.2. The Configuration of the UBEX Matrix
For the sake of simplicity the configuration steps of the switch are
explained through a valid UBEX matrix example which contains:
Device
Pieces Firmware version
Netgear M4300-24X24F
1
UBEX-MMU-X200
1
UBEX-PRO20-HDMI-F100
6
6.3. First Steps
6.3.1. Installation of the UBEX Devices
The installation steps of the endpoint and the MMU devices can be
found in the
Connecting Steps
section.
6.3.2. Installation of the Switch
Download the user's manual for the M4300-24X24F model from the
website of the vendor and follow the instructions.
Step 1. Install the switch correctly based on the instructions of the
model.
Step 2. Plug the cables between the UBEX endpoints and the switch
based on the following options:
12x 10GbE singlemode/multimode SFP+ transceiver modules
and 12x singlemode/multimode fiber optical cables
12x 10GbE DAC cables
Step 3. Plug the cables between the UBEX MMU and the switch based
on the following options:
M4300-24X24F
®
1x 1GbE singlemode/multimode SFP transceiver module and a
singlemode/multimode fiber optical cable
1x 1GbE singlemode/multimode DAC cable
1x CATx cable
Step 4. Connect a control device (e.g. a laptop) to the switch with a
CATx cable to one of the following ports:
OOB port
Any 10G copper port
Firmware ver.: 12.0.2.9
Boot ver.: 1.0.0.8
1.0.0
The factory default settings of the switch:
1.1.0
IP address of the OOB port: 192.168.0.239
IP address of the copper ports: 169.254.100.100
Control Device Settings
Before connecting to the switch be sure the network settings of the
operating system on your computer are correct. You need to set the
following setting in the network card:
IP address: must be in the in the same subnet : 192.168.0.x with
the subnet mask of 255.255.255.0
Step 5. Open a web browser on your computer and follow the
configuration steps coming in the following section.