5. Configuration Steps - Ubiquiti EdgeSwitch 16 XG

5
C onfiguration Steps - Ubiquiti EdgeSwitch 16 XG
The following chapter describes and explains step-by-step the procedure of
the configuration for the Ubiquiti EdgeSwitch 16 XG fully managed network
switch:

Description

Î

The Configuration of the UBEX Matrix

Î

First Steps

Î
Detailed Instructions
Î
Finalizing the Matrix
Î
Installation and Network Setup Guide for UBEX
5.1. Description
This chapter helps you configure the Ubiquiti EdgeSwitch
fully managed switch for the UBEX matrix. This model of the Ubiquiti
contains 12x 10G SFP+ slots which are enough to serve 6 UBEX
endpoints and handle up to 12 source / destination devices. The
switch is recommended for small businesses.
5.2. The Configuration of the UBEX Matrix
For the sake of simplicity the configuration steps of the switch are
explained through a valid UBEX matrix example which contains:
Device
Pieces Firmware version
Ubiquiti EdgeSwitch 16 XG
1
UBEX-MMU-X200
1
UBEX-PRO20-HDMI-F100
6
5.3. First Steps
5.3.1. Installation of the UBEX Devices
The installation steps of the endpoint and the MMU devices can be
found in the
Connecting Steps
section.
5.3.2. Installation of the Switch
Download the user's manual for the EdgeSwitch 16 XG model from the
website of the vendor and follow the instructions.
Step 1. Install the switch correctly based on the instructions of the
model.
Step 2. Plug the cables between the UBEX endpoints and the switch
based on the following options:
12x 10GbE singlemode/multimode SFP+ transceiver modules
and 12x singlemode/multimode fiber optical cables
12x 10GbE DAC cables
Step 3. Plug a CATx cable to the copper port (UBEX network) of the
UBEX MMU and to one of the copper ports of the switch.
ES-16-XG
TM
Step 4. Connect a control device (e.g. a laptop) to the switch with a
CATx cable to one of the copper ports.
1.7.3 (or above)
The factory default settings of the switch: 192.168.1.2
1.0.0
Control Device Settings
1.1.0
Before connecting to the switch be sure the network settings of the
operating system on your computer are correct. You need to set the
following setting on the network card:
IP address: must be in the in the same subnet : 192.168.1.x with
the subnet mask of 255.255.255.0)
ATTENTION! The copper ports of the switch accept 1000BaseT
(1 Gbps) Ethernet connection only.
Step 5. Open a web browser on your computer and follow the
configuration steps coming in the following section.