Eneo MCB-64A0003M0A User Manual page 22

1/2.9” hd camera, 2560x1440, day&night, af zoom, wdr, 3.2~9mm, infrared, ip67
Hide thumbs Also See for MCB-64A0003M0A:
Table of Contents

Advertisement

5-1-3. DELAY
D→N DELAY is time in second while camera maintains its status before Day
to Night switches. DELAY can avoid the unwanted/frivolous switching by a
short term lights such as light from the passing car. Sets delay term low,
middle or high.
5-1-4. IR LED CTL
IR LED Control (AUTO/OFF) is available with IR LED model only. If it is set to
OFF, IR LED will be turned OFF but DAY or NIGHT is still determined by the
built-in light photo sensor.
5-2. AUTO
Used when DAY or NIGHT is determined by light level through the lens and DAY
from/to NIGHT is switched automatically by the scene brightness.
It can be controlled the AGC threshold level, AGC margin and delay time.
5-1-1. SMART IR
SMART IR can be set to reduce the saturation by the strong IR illumination in
the night in any menu of EXTERN, AUTO and B/W(NIGHT). Set to ON, SMART
IR is enabled and ANTI-SAT. level is controlled.
5-1-2. ANTI-SAT. (Available only with the SMART IR is ON)
Sets the anti saturation level 0~20. Setting high level avoids the saturation
strongly but the corners will be darker accordingly.
5-2-3. AGC THRES
AGC(Auto Gain Control) is a threshold level which determines to switch DAY
from/to NIGHT in AUTO mode. Higher value makes the camera switch DAY
from/to NIGHT at bright illumination.
5-2-4. AGC MARGIN
Sets the gap level switching from/to DAY(color) or NIGHT(B/W).
5-2-5. DELAY
D→N DELAY is time in second while camera maintains its status before Day
to Night switches. DELAY can avoid the unwanted/frivolous switching by a
short term lights such as light from the passing car.
Sets delay term low, middle or high.
22
5. DAY&NIGHT
SMART IR
OFF
ANTI-SAT.
NOT USED
AGC THRES
10
llllllllllllllllllllll
AGC MARGIN
15
llllllllllllllllllllll
DELAY
MIDDLE
RETURN

Advertisement

Table of Contents
loading

Table of Contents