②At minimum operating environment temperature

2.3 Wire Size

The wiring and installation methods must conform to all national and local electrical
code requirements.
PV Wire Size
Since PV array output can vary due to the PV module size, connection method or
sunlight angle, the minimum wire size can be calculated by the Isc
Please refer to the value of Isc in the PV module specification. When PV modules
connect in series, the Isc is equal to a PV modules Isc. When PV modules connect in
parallel, the Isc is equal to the sum of the PV module's Isc. The Isc of the PV array
must not exceed the controller's maximum PV input current. Please refer to the table
as below:
NOTE: All PV modules in a given array are assumed to be identical.
*Isc=short circuit current(amps) Voc=open circuit voltage.
Model
Tracer1206AN
Tracer1210AN
Tracer2206AN
Tracer2210AN
Tracer3210AN
Tracer4210AN
*These are the maximum wire sizes that will fit the controller terminals.
CAUTION: When the PV modules connect in series, the open circuit
voltage of the PV array must not exceed 46V (Tracer**06AN), 92V
(Tracer**10AN) at 25℃ environment temperature.
Battery and Load Wire Size
The battery and load wire size must conform to the rated current, the reference size
as below:
Model
Tracer1206AN
Tracer1210AN
Tracer2206AN
Tracer2210AN
Tracer3210AN
Tracer4210AN
Max. PV input current
10A
20A
30A
40A
Rated
Rated
charge
discharge
current
current
10A
10A
20A
20A
30A
30A
40A
40A
Max. PV wire size
Battery wire
size
2
4mm
/12AWG
2
6mm
/10AWG
2
10mm
/8AWG
2
16mm
/6AWG
10
of PV array.
2
4mm
/12AWG
2
6mm
/10AWG
2
10mm
/8AWG
2
16mm
/6AWG
Load wire
size
2
4mm
/12AWG
2
6mm
/10AWG
2
10mm
/8AWG
2
16mm
/6AWG

Hide quick links: