CAUTION: The wire size is only for reference. If there is a long distance
between the PV array and the controller or between the controller and the
battery, larger wires can be used to reduce the voltage drop and improve
performance.
CAUTION: For the battery, the recommended wire will be selected
according to the conditions that its terminals are not connected to any
additional inverter.

2.4 Mounting

WARNING: Risk of explosion! Never install the controller in a sealed
enclose with flooded batteries! Do not install in a confined area where
battery gas can accumulate.
WARNING: Risk of electric shock! When wiring the solar modules, the PV
array can produce open circuit voltages in excess of 100V when in
sunlight.
CAUTION:The controller requires at least 150mm of clearance above and
below for proper air flow. Ventilation is highly recommended if mounted in
an enclosure.
Installation Procedure:
Step 1: Determination of Installation Location and Heat-dissipation Space
Determination of installation location: The controller shall be installed in a place with
sufficient air flow through the radiators of the controller and a minimum clearance of
Figure 2-1 Mounting