STEP 5 – CHARGE MODE
Press the CHARGE button.
STEP 6 – CHARGING
During normal charging the LCD screen will default to the VOLTS display; to view input
current press the VOLTS/AMPS button.
The LED indicators will also illuminate and flash various signals, indicating the different
stages of charging. Refer to page 9 for a description of LED signals.
When the battery is fully charged, the green FULLY CHARGED LED will illuminate. This
is known as the float stage and the charger can be left connected to the battery without
over charging.
If the red POWER LED is flashing, or the LCD screen displays an error signal, there
is a fault; refer to the "Fault & Errors" explanation on page 14 of this manual.
STEP 7 – DISCONNECTION
Ensure the 240V mains switch is turned off and the charger is disconnected from
the 240V mains power.
Battery out of vehicle
Remove the BLACK lead (battery clip) from the battery.
Remove the RED lead (battery clip) from battery.
Battery in vehicle
Remove the chassis connection.
Remove the battery terminal connection.
LOCKING THE SCREEN AND REMOTE CONTROL
To Lock the buttons on the front of the charger or remote control so the charge rate,
CHARGE and PWR SUPPLY can not be adjusted, press and hold the CHARGE RATE and
CHARGE button for 3 seconds. Doing this will lock the buttons. Repeating this process
will unlock the buttons.