Step 3 - Connect To 240V Mains Power; Step 4 - Set Charge Rate - Projecta INTELLI-CHARGE IC7 Manual

12 volt, 7 stage switchmode
Table of Contents

Advertisement

STEP 2C – CONNECTION IN VEHICLE WITH HARNESS (IC7 ONLY)
Connect the RED ring terminal of the harness to the Positive (+) battery terminal.
Connect the BLACK ring terminal of the harness to the Negative (-) battery terminal.
Connect the plug on the harness to the charger's output lead socket.
STEP 3 – CONNECT TO 240V MAINS POWER
Connect the battery charger to the 240V mains powered socket and turn on the mains
power.
STEP 4 – SET CHARGE RATE
The charge rate should be set according to the size of the battery. See the recommended
charge rates for various battery sizes in the table on the following page.
a. Press the CHARGE RATE or MODE button to enter setting mode.
b. Press the CHARGE RATE button until the desired setting is achieved.
ADJUSTABLE CHARGE RATES: 12 VOLT BATTERIES
Current
AH
CCA
setting
1A
7
20
40
2A
14 40
80
4A
30 80
180 480
6A
40 120
240 720
7A
50 140
300 800
8A
60 160
360 1000
10A
70 200
450 1000
15A
85 300
465 2000
MCA
Time
120
55
170
7–24h
240
110 330
7–24h
250 650
7–24h
330 1000
7–24h
350 900
7–24h
500 1300
7–24h
500 1200
7–24h
600 2500
7–24h
Vehicle harness
LITHIUM
Time
AH
2–10
2–10h
4–20
2–10h
8–40
2–10h
12–60
2–10h
14–70
2–10h
16–80
2–10h
20–100
2–10h
30–150
2–10h
11