Chapter 8 ParametersASDA-A2R Series

8.3 Parameter Description

P0-xx Monitor Parameters

VER
P0-00★
Operational
Interface:
Default: Factory Setting
Control
Mode:
Unit: -
Range: -
Data Size: 16bit
Format: DEC
Settings: This parameter shows the firmware version of the servo drive.
P0-01■
ALE
Operational
Interface:
Default: -
Control
Mode:
Unit: -
Range: 0x0000~0xFFFF: It only can be set to 0 to
Data Size: 16bit
Format: BCD
Settings: Hexadecimal format: displays the alarm code
8-16
Firmware Version
Panel / Software
ALL
Alarm Code Display of Drive
(Seven-segment Display)
Panel / Software
ALL
clear the alarm (Same as DI.ARST).
Alarm of Servo Drive
001:Over current
002:Over voltage
003:Under voltage (In default setting, the alarm occurs only when
the voltage is not enough in Servo ON status; In Servo ON
status, when it applies to power R, S, T, the alarm still will not
be cleared. Please refer to P2-66.)
004 : Motor combination error (The drive corresponds to the wrong
motor)
005:Regeneration error
Communication
Communication
Address: 0000H
0001H
Related Section: -
Address: 0002H
0003H
Related Section:
11.1, 11.2, 11.3
Revision December, 2014