C80 Series Maintenance Manual
4 Failure Diagnosis
Procedures to output the alarm detailed information history data files
(1) Select [Mainte]-[I/O].
(2) Set the files of device A as follows:
A:Dev: Memory
Directory: /LOGEX
File name: ALM-SVn.LOG, ALM-OTRn.LOG (n = 1 to 5)
<Note>
When the menu [List update] is executed, ALM-SV1.LOG to ALM-SV5.LOG and ALM-OTR1.LOG to ALM-
OTR5.LOG are displayed in the list.
(3) Press the menu [Area change] to set the destination of the device B file.
(In this manual, the destination is USB memory as an example.)
B:Dev: USB memory
Directory: Select a destination directory.
File name: Input a file name to save.
<Note>
If you omit the file name, the file is named with the same name as the device A.
(4) Press the menu [Trnsfr A→B] to output the file.
Procedures to view on the edit screen of the history data
(1) On the Mainte screen, select [Mainte] and then [Psswd input] to input the password issued by the MTB.
(2) Select the menu [Edit]-[Open] on the edit screen.
(3) Input the following strings in the input area according to the history data to browse, and then press the [INPUT] key.
- "/LOG/ALLLOG.LOG" for all history data
- "/LOG/KEYLOG.LOG" for key history data
- "/LOG/TOUCHLOG.LOG" for touchscreen history data
- "/LOGEX/ALM-SVn.LOG" (n = 1 to 5) for servo/spindle alarm detailed information history data
- "/LOGEX/ALM-OTRn.LOG" (n = 1 to 5) except for servo/spindle alarm detailed information history data
IB-1501454-C
86