Starting The Data Collection; Stopping The Data Collection - Mitsubishi Electric C80 series Maintenance Manual

Hide thumbs Also See for C80 series:
Table of Contents

Advertisement

C80 Series Maintenance Manual
4 Failure Diagnosis
Menus
Menus
This begins collecting sampling data and history data.
Start
This stops the sampling data and history data collection operation.
Stop
This stops the sampling data and history data collection operation, and clears the collected data.
Data
This is not displayed when "#1263 bit1" is ON.
clear
Note
(1) The alarm history data collection start/stop operation is switched using the menu [Start] or [Stop] of data collection re-
gardless of whether "Alarm history" is set to "0" or "1".

4.11.1 Starting the Data Collection

When the NC is turned ON, the data collection starts automatically according to the settings in "Sampling spec" and "Col-
lecting data select" on the diagnosis data collection setting screen.
After the diagnosis data collection is stopped by pressing the menu [Stop] or [Data clear] on the diagnosis data collection
setting screen, the data collection does not start even if the NC power is turned ON again. In this case, press the menu
[Start] on the diagnosis data collection setting screen to start the diagnosis data collection.
The settings for "Sampling spec" and "Collecting data select" on the diagnosis data collection screen are valid after the NC
power is ON again.
(1) When the menu [Start] is pressed, the confirmation message appears.
(2) Press the [Y] or [INPUT] key to start (restart) the data collection.
Note
(1) Data collection starts even if "Alarm history" is set to "1" (Not collect).

4.11.2 Stopping the Data Collection

The data collection stops when any of the following operations is performed:
Condition to stop data collection (trigger)
Press the menu [Stop] on the support screen.
Press the menu [Data clear] on the support screen.
At the time of the occurrence of servo alarm (emergency
stop state)
At the rising edge of the diagnosis data collection stop sig-
nal (NETSTP)
(1) When the menu [Stop] is pressed, the confirmation message appears.
(2) Press the [Y] or [INPUT] key to stop the data collection.
Press the menu [Start] to restart the data collection. When the data collection is stopped by pressing the menu [Stop],
the data collection is not restarted even when the NC is turned ON again.
Note
(1) Data collection is stopped even if "Alarm history" is set to "0" (Collect).
Details
Target data to stop collection
Sampling data and history data
Sampling data and history data
Sampling data
Sampling data
83
IB-1501454-C