Viewing Dmx Data For The Link (Data); Viewing Lamp Hours (L/Hr); Resetting Lamp Hours (L/Rs) - High End Systems trackspot Bolt User Manual

Table of Contents

Advertisement

Viewing DMX Data for the Link (DATA)

This procedure allows you to use a trackspot Bolt fixture to view DMX channel values all devices
on the DMX link. Use this menu option to:
• Checking current DMX values on this fixture
• Test devices that do not have built-in DMX diagnostics
• Check fixtures that are physically inconvenient to monitor directly
If you experience a problem with a device on the link, use this menu to select a DMX channel in
the device's channel range and view its DMX value. After noting the value of the channel you
selected, use your DMX console to change that channel's value.
If the value of the DMX channel you selected does not change, there may be a problem with the
DMX cable or your transmitting device (i.e. DMX console).
If the DMX channel value changes, but the device does not respond, the device may be faulty.
Consult the documentation provided with that device for more information.
To view DMX data for any device on the DMX link:
1. Press and hold <Menu> until AddR appears on the LED display.
2. Scroll to the INFO menu. Press <Enter> to select.
3. Scroll to the dMX menu. Press <Enter> to select.
4. Scroll to the desired DMX channel (001 – 512). Channel numbers will flash.
5. Press <Enter> The DMX value for the selected channel will be displayed.
Viewing LED Hours (L/HR)
To view the number of hours the LED light engine has spent on since the last reset:
1. Hold <MENU> until the display changes to AddR.
2. Using the up and down buttons, scroll to the INFO field and press <ENTER>.
3. Using the up and down buttons, scroll to the L/HR field and press <ENTER> to view the LED
hours.
Note: If the display indicates OVER, the counter has rolled over 9999 hours.
Resetting LED Hours (L/RS)
To reset LED light engine hours:
1. Hold <MENU> until the display changes to AddR.
2. Using the up and down buttons, scroll to the INFO field and press <ENTER>.
3. Using the up and down buttons, scroll to the L/RS field and hold <ENTER> until the fixture
resets the lamp hours to 0000. DONE displays when the reset is complete.