Performing Self Tests (Self); Moving The Fixture To Setup Position (S/Up) - High End Systems trackspot Bolt User Manual

Table of Contents

Advertisement

CHAPTER 3
The Menu System

Performing Self Tests (SELF)

The following self tests are available:
Parameter
PAN
Moves through the entire pan range
TILT
Moves through the entire tilt range
DIM
Tests LED Dimming function
COLR
Static color wheel function
LT1
Rotating Gobo wheel movement
LT1R
Rotating Gobo wheel: rotating gobo movement
LT2
Static Gobo wheel movement
IRIS
Tests Iris function
FCUS
Moves through the Focus range
To start a self test process:
1. Press and hold <Menu> until AddR appears on the LED display.
2. Scroll to the TEST menu. Press <Enter> to select.
3. Scroll to the SELF menu. Press <Enter> to select.
4. Scroll to the desired option (listed above).
5. Press <Enter> to start the test. The fixture will perform the selected self test.
6. Press <Menu> to exit the test.

Moving the Fixture to Setup Position (S/UP)

Caution: The setup position is used only by qualified service
To place the fixture in setup position before servicing:
1. Hold <MENU> until the display changes to AddR.
2. Using the up and down buttons, scroll to the TEST field and press <ENTER>.
3. Using the up and down buttons, scroll to the S/UP field and press <ENTER>. The display will
indicate SET NOW while the motors are electronically locked into place.
4. Perform the appropriate maintenance procedures.
5. Press <MENU> to reset and home the fixture.
24
Self-Test Description
personnel during maintenance.