Optional 1 To 8 Remote Units For Cable Mapping - Pro'sKit MT-7071 User Manual

Lcd cable length toner & probe kit
Table of Contents

Advertisement

Cable mapping with multi remotes (ID#1~#8)(MT-7071K)
Caution!
When performing cable map with multi remotes (ID#1~#8), it will indicate
ID number of remote unit, but not show up shielded or unshielded wire.
The remote unit does not have buzzer alarm.
When performing cable map with multi remotes (ID#1~#8), the test
result of connector pins are the pairs defined by this standard as below:
Lan cable: #1pin & #2pin、#3pin & #6pin、#4pin & #5pin、#7pin & #8pin
Phone cable #1pin & #6pin、#2pin & #5pin、#3pin & #4pin.
In the test result of verifying cable status and wire troubleshooting with
multi remotes (ID#1~#8), when Lan cable #1pin circuit is open, it will
show #1pin & #2pin open. When the telephone cable #1pin circuit is
open, the result will show #1pin & #6pin open. If users want to know
more pin to pin detail of cable status, we recommend you change to
perform cable mapping for 1 to 1 standard remote unit, please refer to
chapter "Cable mapping with standard remote unit".
When performing 1 to 8 remote unit (ID#1~#8) cable mapping, if LCD
displays two pairs #3pin & #6pin、#4pin & #5pin interaction flashing, it
means cross over between #3pin & #6pin、#4pin&#5pin (not comply with
EIA/TIA568A/B standard) or the patch cord is too short。
Performing 1 to 8 remote unit (ID#1~#8) cable mapping for RJ11/RJ12
6P/6C,6P/4C,6P/2C telephone cable, the result instruction as shown as
figure 5-1.
1.
Please connect tested cable to transmitter and remote unit properly as
shown in figure 3.
2.
Please refer to page30「Operating process chart B. Type:)」to select
the corrected cable type (such as coaxial cable, telephone cable...).
Start to perform cable mapping test as page30 「Operating process
3.
chart C. Cable Mapping」.
4.
The test result of cable map with multi remote units will display on LCD,
please refer to figure 5-2.
5.
When performing cable mapping with multi remotes (ID#1~#8) for Lan
cable, phone cable (6P6C), we use ID#6 as a example, if cable status is
"good connection", the remote unit will sound five of beeps; If the cable
status is "open", the remote unit will sound beeps continuity; if status is
"short" no more beep sounded. The test result instruction, please refer to
figure 5-2.