OVERVIEW MT-7029 with EMI filters to eliminate high frequency noise, for which allows user to quickly locate and verify the cable status and troubleshoot wiring for continuity, shorts, opens and crossover on RJ45, Lan cable Cat 5、5e、6 (UTP/STP), RJ11/12 telephone cable...
Page 4
Low battery display 6.5V (Power LED flashes) Battery type DC 9.0V (NEDA 1604/ 6F22 DC9V ×1pce) Dimension (L×W×D) 138×80×35 mm Weight 140g MT-7029 Receiver specifications Frequency 130KHz ≦115mA The Max. working current Compatible connectors RJ45(8 pin)/RJ11(6 pin) 4 Position mode switch (LED、NCV、OFF、...
Page 5
Safety Information Never use the Transmitter or Receiver on live circuits of more than DC48V or it will result damage. Never use the Transmitter, Receiver or test wire if they are damaged. Inspect the cases and test leads for damage before use.
Page 6
MT-7029 Transmitter: Do not connect with DC 48V live circuit equipment or it will result damage. Figure1. MT-7029 Transmitter Diagram 1. 「 TEST」 : RJ45(8 pin)/ RJ11 (6/4/2 pin) cable mapping test socket. 2.「SCAN」: RJ11(6 pin) socket. 3.「SCAN」RJ45 socket. Caution! Do not plug in any live cable over DC 48V to the transmitter socket.
Page 7
」Cable map & Shielded function button 18.「 」Phone line polarity function button 19.「 20. Battery cover Figure 2. MT-7029 Receiver Diagram 1. Probe:Used for cable tracing and NCV detection. 2. LED light 3. Power ON/OFF indicator 4. NCV indicator 5. Signal status indicator 6.
Caution • The position on the MT-7029 lets you use the Receiver to trace using an analog 130KHz tone. When using the Receiver to isolate the tone source in the cable bundle or at the patch panel, the signal might be interfered with or decreased and the signal will not pass through metal tubes.
Page 9
decrease the battery life time, may occur according to different PoE equipments, and it is normal. To locate cables, do the following steps (Figure 3): 1. Connect the black alligator clip of the Transmitter to the ground, and then connect the red clip to a jack or punch-down block as shown in Figure 3.
Page 10
If cables are connected to the switches, it may not easy to find the signal from MT-7029; please try to turn off the switches or pull out the cable 1 pce a time to check the signal. If signal is still hard to found, use "...
Page 11
RJ45/RJ11 “TEST socket” on the transmitter. Do not use RJ45 SCAN or RJ11 SCAN socket. • You can use the MT-7029 Transmitter or Receiver to validate the cable map on RJ45/RJ11 by RJ45/RJ11compatible connector on transmitter. The cable map function finds the most common wiring faults on twisted pair cabling: shorts, opens, and crossed pairs.
Page 12
Transmitter cable map, 6P/6C each second from 2 to 7 in sequence, 6P/4C each second from 3 to 6 in sequence, 6P/2C each second from 4 to 5 in sequence is synchronized with the MT-7029 Receiver cable map. If it encounters an empty line, the indication will cease.
Page 13
Figure 6 Different Connector’s Cable Map You can use the MT-7029 to validate the cable map on RJ11 and RJ45 connectors. The cable map function finds the most common wiring status on twisted pair cabling: good, shorts, opens, and crossed pairs as shown in Figure 5.
Page 14
TEST green LED light will be off and the product will be standby for next operation. 3. When the “1~8, G” LED indicator on MT-7029 transmitter lighted one by one, the cable (1~8, G) is good. If any of LED indicator is...
Page 15
Figure 8 Cable testing on working line Coaxial Cable & Continuity Testing: DANGER Before testing, please be sure the power of receiver is OFF. To validate cable shield during cable map tests, do the following as: 1. Connect the Transmitter to the circuit as shown in Figure 9. Connect the test leads to the coaxial cable to be tested.
Page 16
Figure 9 Coaxial Cable & Continuity Test Validating Telephone Service and Polarity: Please follow the following steps to check the polarity of telephone lines: 1. Connect the red and black alligator clip of the Transmitter to the telephone line jack or socket or punch-down block. 2.
Page 17
AC power. 1. Turn the switch to “NCV”, the function is started when the power indication is on. 2. When doing the NCV testing, place the probe of MT-7029 receiver to the tested cable, the NCV indicator twinkled fast and...
Page 18
the buzzer sounded means the tested objective is with AC 90~1000V. If the indicator did not come on and no buzzer sounded, it means the tested objective with AC power less than 90V or there is no AC power on it. Maintenance &...
Page 19
Switch at SCAN position, and push “SCAN ” NCV NOT WORK button; If the indicator did not light up, please replace with a new battery Device damaged: please return the product Others to the place you purchased for maintenance.