Panel
Description
Network
Execute a network factory reset. Network settings
Factory Reset
may be reset to the following default values.
Projector Name = Christie@ + Serial Number
Show Network Messages = ON
LAN Setting
Sets if the projector must obtain an automatically
Panel
assigned IP address through DHCP or if the user sets
the address manually.
WLAN Setting
Enables or disables the wireless LAN of the projector. Enter the IP address range, netmask, and
Panel
SNMP Panel
Provides network administrators with a common
way to manage their network devices from a single
remote location.
Administrators can use the Simple Network
Management Protocol (SNMP) interface to query a
number of devices to see their current status or
configuration.
Operators can change configuration values and
configure trap notifications to be sent when certain
events occur (for example, loss of signal, power
state change, and so on).
Emails are sent to the mail server configured in the
projector settings. Up to two user email accounts
can be selected. Important information regarding
the event is located in the body content of the email.
SNMP Traps are notifications sent from the projector
and are only received by a trap receiver (MIB
Browser) in the computer.
GS Series 630-635 User Manual
020-001213-02 Rev. 1 (02-2018)
Fields
LAN settings:
• Manual
• IP Address = 192.168.0.100
• Subnet Mask = 255.255.255.0
• Default Gateway = 192.168.0.100
WLAN settings:
• Enabled
• Start IP = 192.168.1.100
• End IP = 192.168.1.120
• Subnet Mask = 255.255.255.0
• Default Gateway = 192.168.1.100
SNMP settings:
• SNMP Read Community = private
• Trap IP Address = 0.0.0.0
• SMTP IP Address = 0.0.0.0
• All other settings are cleared or
blanked
Trap Configuration:
• All items = SNMP Trap + Email
For the TCP/IP setting, enter the IP
address, netmask, and default gateway
address.
default gateway for the wireless LAN.
• SNMP Read Community (default
setting: private)—Plain text password
that must also be entered in the MIB
browser. This password allows various
settings in the projector to be queried.
• SNMP Location (default setting:
blank)—Use as a description to where a
projector is located in a building. SNMP
emails sent specify this location.
• Trap IP Address (default setting:
0.0.0.0)—Fill in this field with the IP
address of the computer, on which you
want to view received traps from the
projector.
• Trap Email 1/2 (default setting:
Blank)—Set the Trap Email 1 and 2 to
an email address configured under the
mail server entered in the SMTP Server
IP Address field.
• Email from Address (default setting:
blank)—Set the name of the source of
the SNMP emails.
• SMTP Server IP Address (default
setting: 0.0.0.0)—Enter the IP address
of the mail server.