Maintenance And Troubleshooting - Pro-Form PFEX78918P.0 User Manual

Table of Contents

Advertisement

MAINTENANCE AND TROUBLESHOOTING

MAINTENANCE
Regular maintenance is important for optimal
performance and to reduce wear. Inspect and properly
tighten all parts each time the exercise bike is used.
Replace any worn parts immediately.
To clean the exercise bike, use a damp cloth and a
small amount of mild detergent. IMPORTANT: To
avoid damage to the console, keep liquids away
from the console and keep the console out of
direct sunlight.
CONSOLE TROUBLESHOOTING
If the console display becomes dim, replace the
batteries (see assembly step 8 on page 10); most
console problems are the result of low batteries.
If the console does not display your heart rate when
you use the handgrip heart rate monitor, see step 4 on
page 15.
If the message CH0 or CH1 appears in the display
when you press the increase and decrease buttons,
see assembly step 9 on page 10. Disconnect the
console wire from the reed switch wire, and then recon-
nect the wires; make sure to align the connectors
properly and make sure to press the connectors
together firmly.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted. First, turn the resis-
tance knob to the lowest setting.
Next, see the EXPLODED DRAWING on page 23.
Identify the Shields (10, 12). Loosen the Screws
(21, 69) in the Shields, and carefully remove the Shield
Cover (11).
Next, locate the Reed Switch (45), and slide it upward
or downward slightly. Then, turn the pedals for a
moment and see whether the console displays correct
feedback. Repeat this step until the console displays
correct feedback.
When the console displays correct feedback, reattach
the Shield Cover (11).
19
11
10, 12
45