Technical Data - Beko DRYPOINT M eco control Installation And Operational Manual

Drying system
Table of Contents

Advertisement

EN

2.9. Technical data

Technical data
Size of DRYPOINT
M plus
®
Min./max. Operating overpres-
sure
Excess pressure protection
housing
Min./max.
storage/transport temperature
Min./max. Ambient temperature
Min./max. media temperature
Medium
Medium and quality at diaphragm
dryer inlet
Noise level
Installation position
Weight [kg]
Materials
Integrated nanofilter
Pressure loss
PDP outlet settings
PDP difference settings
Electrical data
Operating voltage
Power consumption
Recommended wire cross-section
Recommended connection cable
Protection class
Min./max. contact spring load
(potential-free contact)
Signal output
Interfaces
DRYPOINT
M eco control
®
DEC 1-30S
DEC 2-40S
DEC 3-60S
10-41
10-47
20-48
Only neutral medium in accordance with PED 2014/68/EU with Class [3: - :3] ISO 8573-1
3.4
3.6
4.9
95 ... 240 VAC ± 10% (50 ... 60 Hz) / 100 ... 125 VDC ± 10% 
or 24 ... 48 VAC ± 10% (50 ... 60 Hz) / 18 ... 72 VDC ± 10%
maximum 20 VA (W) with permanently closed solenoid valve
DEC 4-80S
DEC 5-115S
20-53
20-60
4 ... 10 bar
Pressure compensation plug
+2 ... +50 °C,
+2 ... +50 °C,
+2 ... +50 °C,
Fluid group 2: Compressed air/nitrogen
<< 45 dB (A), no expansion pop
Vertical
5.2
5.5
Media-contacting parts as corrosion-proof
Materials conforming to RoHS and REACH regulations
Plastic components conforming to UL regulations
0.01 µm / 0.005 mg/m³
0.1 - 0.3 bar, depending on compressed air volume flow
+10 / +7 / +5 / +3 / 0 / -5 / -10 / -15 / -20 / -26 °C
10 / 15 / 20 / 25 / 30 / 35 / 40 / 45 / 50 / 55 K (Kelvin)
min. 0.5 mm²
2-wired, diameter 5 ... 10 mm
IP 54
max. 12 VAC / 1 A or 24 VDC / 1 A; min. 5 VDC / 10 mA
4...20 mA (PDP outlet)
2 x cable connection M16, cable diameter 5 ... 10 mm
Installation and operation manual
DEC 6-135S
DEC 7-165S
DEC 8-250S
20-67
40-61
40-75
5.8
10.9
12.0
DEC 9-330S
40-90
13.1
17