Error or fault pattern
Error signal upon switching
on unit
Settings cannot be changed
No power supply (green
power LED not lit)
DRYPOINT
M eco control
®
Possible causes
Required performance parameters not yet
reached
PCB fault
Both buttons not pressed simultaneously
Button not held long enough
Button physically damaged
Incorrect supply voltage
PCB fault
Unit overheating
Installation and operation manual
Remedy
The moment the set performance range is
reached, the error message is automatically
reset (latest after 10 to 15 minutes)
→ otherwise, identify cause of the problem: 
The flashing rate of the red LED indicates 
the type of the fault; if necessary, contact 
manufacturer
Contact manufacturer: if necessary, return 
unit for repair or replace control unit
See chapter ... "Operation": Correct button 
operation, testing with solenoid valve
See chapter ... "Operation": Press the 
buttons for approx. 0.2 sec.
Contact manufacturer: if necessary, return 
unit for repair or replace control unit
Check the supply voltage to ensure that it
corresponds to that specified on the type 
plate
Contact manufacturer: if necessary, return 
unit for repair or replace control unit
The unit automatically resumes operation
when the internal temperature has dropped
<60°C